GCB13-00155
| GCB-Fndatn/slab ins/fld vent | 12/16/2013 | 12/18/2013 | 12/18/2013 3:56:38 PM | P | FAIL |
|
|
Huron ###-####. conc. in stemwall already placed. Footing concrete placed yesterday 12-17-13. cold wheather conc. proceedures not followed. Surface temp of concrete must maintain 50 F. for72hrs. Called Heron and noted to him that additional testing is required to show concrete has made 2500 psi.
|
GCB12-00156
| GCB-Fndatn/slab ins/fld vent | 12/17/2013 | 12/18/2013 | 12/18/2013 3:28:55 PM | P | PART |
|
|
Herb ###-#### Foundation pour at 1:30. Spoke therb. concrete has been placed. special inspector on site.
|
GCB13-00128
| GCB-Final | 12/18/2013 | 12/18/2013 | 12/18/2013 3:21:59 PM | P | PART |
|
|
###-#### This is for temporary C of O for office portion only. Temp occ. ok only for front office and bathrooms on existing 2nd. level. must have all other trades signed off as temp. occ also.
|
GCB13-00152
| GCB-Framing | 12/18/2013 | 12/18/2013 | 12/18/2013 2:30:39 PM | P | PART |
|
|
Added inspection. Incorrect time on last inspection.
|
BLD13-03371
| BLD-Final | 12/17/2013 | 12/18/2013 | 12/18/2013 2:29:38 PM | P | PASS |
|
|
Please call ahead for access - Dan Phone #: ###-####. Ok for perm occ.
|
GCB13-00152
| GCB-Framing | 12/17/2013 | 12/18/2013 | 12/18/2013 2:10:25 PM | A | PART |
|
|
Steve ###-#### This is on back bathroom wall. Does not have the required min 42'' clear width in hallway between restrooms. Will reframe the non structural bathroom wall, replacing the steel studs with 2x4 framed wall to gain the requied clear width.
|
BLD13-02929
| BLD-Framing/Rough-in | 12/18/2013 | 12/18/2013 | 12/18/2013 2:03:06 PM | P | FAIL |
|
|
Cameron Phone #: ###-####. Nail 2ply common girder as per truss engineering and provide additional stud at north bearing. Nail 2ply hip girder as per truss engineering. Complete lateral bracing on A1, A2, A5, AAH3, AAH4, AH3, AH8, BH6 and CH2 trusses. Strap double top plate splice at interior wall before radius. Block and nail off interior wall brace panel. Provide aditional nailing on 2x6 to LVL for patio or strap. Ok to insulate. Correction notice posted.
|
ESC13-00589
| Site Final | 12/18/2013 | 12/18/2013 | 12/18/2013 10:08:25 AM | A | DONE |
|
|
|
ESC13-00589
| DOC - Permit Finaled | 12/18/2013 | 12/18/2013 | 12/18/2013 10:08:16 AM | P | PASS |
|
|
|
BLD13-01647
| BLD-Final | 12/17/2013 | 12/18/2013 | 12/18/2013 10:08:01 AM | A | PASS |
|
|
charlie PLEASE call before going out Phone #: ###-####
|
BLD13-01647
| DOC - Permit Finaled | 12/18/2013 | 12/18/2013 | 12/18/2013 10:07:47 AM | P | PASS |
|
|
|
GCB13-00085
| GCB-Fire Wall | 12/17/2013 | 12/18/2013 | 12/18/2013 9:21:13 AM | A | PART |
|
|
Dante ###-####. East firewall, exterior 5/8 rock ok to cover.
|
GCB13-00118
| GCB-Energy | 12/17/2013 | 12/18/2013 | 12/18/2013 8:56:20 AM | A | PASS |
|
|
Willie ###-####
|
MIS12-00118
| MIS-Aging Inspection | 12/18/2013 | 12/18/2013 | 12/18/2013 8:09:00 AM | | DEFR |
|
|
Mech. needs to sign off.
|
BLD07-01179
| DOC - Permit Expired | 12/18/2013 | 12/18/2013 | 12/18/2013 8:07:31 AM | A | PASS |
|
|
Permit is expired. Has been more than 1 year since last required inspection. Homeowner will have to apply for another permit when they are ready to comlete job.
|
MIS13-00139
| DOC - Permit Finaled | 12/18/2013 | 12/18/2013 | 12/18/2013 8:03:53 AM | P | PASS |
|
|
A permit has been issued and picked up.
|
MIS13-00032
| MIS-Aging Inspection | 12/18/2013 | 12/18/2013 | 12/18/2013 8:01:56 AM | | DEFR |
|
|
Pending electrical.
|
MIS13-00009
| MIS-Aging Inspection | 12/18/2013 | 12/18/2013 | 12/18/2013 7:35:23 AM | | PASS |
|
|
|
MIS13-00009
| DOC - Permit Finaled | 12/18/2013 | 12/18/2013 | 12/18/2013 7:35:12 AM | P | PASS |
|
|
A co has been issued. All trades have finaled.
|