Inspections for the day of: Wednesday, December 18, 2013.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GCB13-00155 GCB-Fndatn/slab ins/fld vent12/16/201312/18/201312/18/2013 3:56:38 PMPFAIL
Huron ###-####. conc. in stemwall already placed. Footing concrete placed yesterday 12-17-13. cold wheather conc. proceedures not followed. Surface temp of concrete must maintain 50 F. for72hrs. Called Heron and noted to him that additional testing is required to show concrete has made 2500 psi.
GCB12-00156 GCB-Fndatn/slab ins/fld vent12/17/201312/18/201312/18/2013 3:28:55 PMPPART
Herb ###-#### Foundation pour at 1:30. Spoke therb. concrete has been placed. special inspector on site.
GCB13-00128 GCB-Final12/18/201312/18/201312/18/2013 3:21:59 PMPPART
###-#### This is for temporary C of O for office portion only. Temp occ. ok only for front office and bathrooms on existing 2nd. level.
must have all other trades signed off as temp. occ also.
GCB13-00152 GCB-Framing12/18/201312/18/201312/18/2013 2:30:39 PMPPART
Added inspection. Incorrect time on last inspection.
BLD13-03371 BLD-Final12/17/201312/18/201312/18/2013 2:29:38 PMPPASS
Please call ahead for access - Dan Phone #: ###-####. Ok for perm occ.
GCB13-00152 GCB-Framing12/17/201312/18/201312/18/2013 2:10:25 PMAPART
Steve ###-#### This is on back bathroom wall. Does not have the required min 42'' clear width in hallway between restrooms. Will reframe the non structural bathroom wall, replacing the steel studs with 2x4 framed wall to gain the requied clear width.
BLD13-02929 BLD-Framing/Rough-in12/18/201312/18/201312/18/2013 2:03:06 PMPFAIL
Cameron Phone #: ###-####. Nail 2ply common girder as per truss engineering and provide additional stud at north bearing. Nail 2ply hip girder as per truss engineering. Complete lateral bracing on A1, A2, A5, AAH3, AAH4, AH3, AH8, BH6 and CH2 trusses. Strap double top plate splice at interior wall before radius. Block and nail off interior wall brace panel. Provide aditional nailing on 2x6 to LVL for patio or strap. Ok to insulate. Correction notice posted.
ESC13-00589 Site Final12/18/201312/18/201312/18/2013 10:08:25 AMADONE
ESC13-00589 DOC - Permit Finaled12/18/201312/18/201312/18/2013 10:08:16 AMPPASS
BLD13-01647 BLD-Final12/17/201312/18/201312/18/2013 10:08:01 AMAPASS
charlie PLEASE call before going out Phone #: ###-####
BLD13-01647 DOC - Permit Finaled12/18/201312/18/201312/18/2013 10:07:47 AMPPASS
GCB13-00085 GCB-Fire Wall12/17/201312/18/201312/18/2013 9:21:13 AMAPART
Dante ###-####. East firewall, exterior 5/8 rock ok to cover.
GCB13-00118 GCB-Energy12/17/201312/18/201312/18/2013 8:56:20 AMAPASS
Willie ###-####
MIS12-00118 MIS-Aging Inspection12/18/201312/18/201312/18/2013 8:09:00 AM DEFR
Mech. needs to sign off.
BLD07-01179 DOC - Permit Expired12/18/201312/18/201312/18/2013 8:07:31 AMAPASS
Permit is expired. Has been more than 1 year since last required inspection. Homeowner will have to apply for another permit when they are ready to comlete job.
MIS13-00139 DOC - Permit Finaled12/18/201312/18/201312/18/2013 8:03:53 AMPPASS
A permit has been issued and picked up.
MIS13-00032 MIS-Aging Inspection12/18/201312/18/201312/18/2013 8:01:56 AM DEFR
Pending electrical.
MIS13-00009 MIS-Aging Inspection12/18/201312/18/201312/18/2013 7:35:23 AM PASS
MIS13-00009 DOC - Permit Finaled12/18/201312/18/201312/18/2013 7:35:12 AMPPASS
A co has been issued. All trades have finaled.