Inspections for the day of: Thursday, December 18, 2014.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-05150 Rough-in12/18/201412/18/201412/18/2014 4:24:48 PMPPASS
Ron-insulation of a stove-please call prior to meet-homeowner called in the inspection Phone #: ###-####
MEC14-05470 Final12/17/201412/18/201412/18/2014 4:03:40 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dan Otero - need to sleeve the gas flex where it penetrates the fireplace in the basement
MEC14-05470 Rough-in12/17/201412/18/201412/18/2014 4:02:53 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dan Otero - need to sleeve gas flex where it penetrates the fireplace
MEC14-05544 Final12/18/201412/18/201412/18/2014 3:21:03 PMPPASS

Customer Name: Melissa Biser ###-#### Tech: Jason Baxter ###-####. Need to coordinate PVC flue test at or around 3:30/4:00 pm. Phone #: ###-#### Inspection requested via web by cheryl shroll Inspection cancelled from web by: cheryl shroll






Phone #: ###-#### Inspection requested via web by cheryl shroll
MEC14-04355 Rough-in12/17/201412/18/201412/18/2014 2:49:46 PMPPASS
JOB CONTACT - CHRIS ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - 60lb gas pass
MEC14-05263 Final12/15/201412/18/201412/18/2014 2:34:16 PMPFAIL
CALL CHRIS(TENANT) WHEN ON THE WAY. REQUESTS LATE AFTERNOON Phone #: ###-#### Inspection requested via web by PAM SCHANK - need to pressure test pvc flue.
MEC14-01708 Final12/18/201412/18/201412/18/2014 2:04:19 PMPPASS
MEC14-04690 Final12/18/201412/18/201412/18/2014 1:56:23 PMPPART
TEMP Final - Call Jim Little 30 mins prior ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann - temporary okay.
MEC14-03775 Rough-in12/18/201412/18/201412/18/2014 12:28:52 PMPPASS
JOB CONTACT - JUSTIN ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - 60lb gas pass
MEC14-05497 Pressure Test12/11/201412/18/201412/18/2014 11:43:18 AMAPASS
Late A.M. p/t please
Miguel ###-#### installer Phone #: ###-#### Inspection requested via web by Dustin Rich - 20lb gas pass
MEC14-05544 Final12/17/201412/18/201412/18/2014 11:15:26 AMPCANC
Customer Name: Melissa Biser ###-#### Tech: Jason Baxter ###-####. Need to coordinate PVC flue test at or around 3:30/4:00 pm. Phone #: ###-#### >> Inspection requested via web by cheryl shroll Inspection cancelled from web by: cheryl shroll
MEC14-05565 Final12/17/201412/18/201412/18/2014 11:03:24 AMAPASS
zack Phone #: ###-####
MEC14-05528 Final12/16/201412/18/201412/18/2014 10:43:02 AMAPASS
Please be there before 10:30am with call on way Jenny ###-#### or ###-####. Thanks Phone #: ###-#### Inspection requested via web by Allie Courter
MEC14-05430 Conference12/18/201412/18/201412/18/2014 10:42:41 AMADONE
IRC- G2406.2 A 80percent furnace may not be installed in a bathroom or a space that open only into a bathroom, unless the appliance is installed in a room or space that opens only into a bathroom and such space is used for no other purpose and is provided with a solid weather-stripped door equipped with a approved self closing device and all combustion air is taken directly from the outdoors in accordance with section G2407.6.
MEC14-05607 Final12/17/201412/18/201412/18/2014 10:14:55 AMAPASS
Homeowner: Chris Williams Ph####-#### Inspection requested via web by Jason Robinson
MEC14-05607 Final12/17/201412/18/201412/18/2014 10:14:54 AMAPASS
Homeowner: Chris Williams Ph####-#### Inspection requested via web by Jason Robinson
MEC14-05607 Pressure Test12/17/201412/18/201412/18/2014 10:14:53 AMAPASS
Homeowner: Chris Williams Ph####-#### Inspection requested via web by Jason Robinson - 20lb gas pass
MEC14-05556 Rough-in12/18/201412/18/201412/18/2014 8:47:14 AMAFAIL
the sos switches for the condensate are on back order from our supply house, we will install them on final Phone #: ###-#### Inspection requested via web by Troy Worley - Exhaust fans not installed yet.
MEC14-05556 Pressure Test12/18/201412/18/201412/18/2014 8:42:24 AMAPASS
the sos switches for the condensate are on back order from our supply house, we will install them on final Phone #: ###-#### Inspection requested via web by Troy Worley - 20lb gas pass
MEC14-04793 Final12/18/201412/18/201412/18/2014 7:41:32 AMACANC
Phone #: ###-#### >> Inspection requested via web by Troy Worley Inspection cancelled from web by: Troy Worley
MEC13-03623 Mec-Aging Inspection12/18/201412/18/201412/18/2014 6:32:52 AM CANC
No calls