ELE13-03415
| ELE-Aging Inspection | 12/18/2017 | 12/18/2017 | 12/26/2017 2:34:51 PM | | PASS |
|
|
Drove by and inspected.
|
ELE17-02649
| Electrical Rough-In | 12/15/2017 | 12/18/2017 | 12/18/2017 3:03:31 PM | P | PASS |
|
|
contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell Discussed required work clearence for control panels on VAV units located above grid. Minimum of 18" deep and 24" wide as per Daryl DeGrange for tight spaces. Other areas shall have full required by voltage present. 3 more extended stay rooms and janitors closet as noted on contractor print. Wall rough in ok cover
|
ELE17-02310
| Final | 12/18/2017 | 12/18/2017 | 12/18/2017 2:07:48 PM | P | FAIL |
|
|
Homeowner will be available 2 walkthrough. Phone #: ###-#### Inspection requested via web by Casey Fouts 210.8- All garage 120 volt receptacles shall have GFCI protection. Garage refrigerator. 406.6- Old receptacle in brick in craft room is a grounded type receptacle on a ungrounded circuit. Blank, change to 2 wire receptacle or GFCI protect grounding type receptacle. No code violation shall be retained. 408.4- Circuit directory shall be complete on sub panel and service panel.
|
ELE17-03026
| Final | 12/14/2017 | 12/18/2017 | 12/18/2017 12:47:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Final ok
|
ELE17-02732
| Final | 12/14/2017 | 12/18/2017 | 12/18/2017 12:47:06 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 210.8(B)- All 120 volt receptacle outlets located with in 6' of a sink shall have GFCI protection. Mother's room. 314.25- Furniture outlets and covers shall be install. If outlets are not being used on furniture blanks shall be installed due to live spade connectors exposed. See RI for IT room ceiling violations.
|
ELE17-02732
| Electrical Rough-In | 12/14/2017 | 12/18/2017 | 12/18/2017 12:41:06 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 314.29- Access shall be provided for electrical boxes. HVAC equipment above grid blocks access panel for existing elevator shaft acess which has electrical located in it. Minimum of 90 degrees for door swing shall be provided. 400.12- Flexible cords shall not be run above or pass thru grid. Receptacle has been relocated however pump has not which has flexible cord.
|
ELE17-01536
| Permanent Service | 12/15/2017 | 12/18/2017 | 12/18/2017 9:54:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jeremy Cloud Training and safety building. 9,500 Available fault current. p/s u/g n ok
|
ELE17-01537
| Permanent Service | 12/15/2017 | 12/18/2017 | 12/18/2017 9:53:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jeremy Cloud Admin classroom building. 9,500 Available fault current. p/s u/g n ok
|
ELE17-04230
| Rough-In Permanent Service | 12/16/2017 | 12/18/2017 | 12/18/2017 9:12:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Murray Rough in ok cover p/s u/g n ok
|
ELE17-04057
| Electrical Rough-In | 12/17/2017 | 12/18/2017 | 12/18/2017 8:33:13 AM | A | PASS |
|
|
call one half hour before inspection to ensure building is unlocked Phone #: ###-#### Inspection requested via web by Steve Craig Wall rough in ok cover
|