Inspections for the day of: Monday, December 19, 2016.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-03048 Final12/19/201612/19/201612/19/2016 2:47:57 PMPPART
0152 Phone #: ###-#### Inspection requested via web by robert goodson.
1. Install a thermal expansion tank on the cold side of the water heater and downstream of the double check valve. 608.3
2. Install a double check valve or RP (per plans), for the commercial coffee maker.
3. Install a temperature limiting device on the public restroom faucet that meets ASSE 1070.
413.1.
PLM16-03850 Final12/19/201612/19/201612/19/2016 1:52:40 PMPPART
Phone #: ###-#### Inspection requested via web by Todd Walter. Cauik behind all sinks, add a second tether and shorten the existing tether to the pizza oven, and install the chemical dispenser.
PLM16-00903 PLM-Aging Inspection12/19/201612/19/201612/19/2016 11:25:11 AM PEND
contractor to schedule with tenant.
PLM16-01685 PLM-Aging Inspection12/19/201612/19/201612/19/2016 9:26:24 AM PASS
PLM16-01685 DOC - Permit Expired12/19/201612/19/201612/19/2016 9:26:07 AMAPASS
Spoke with the homeowner. Never installed the sink and sold the house.
PLM16-04446 Water Heater Final12/19/201612/19/201612/19/2016 9:16:31 AMAPASS
PLM16-00032 Water Heater Final12/19/201612/19/201612/19/2016 9:15:20 AMACANC
PLM16-04606 Final12/16/201612/19/201612/19/2016 9:08:44 AMAPASS
please inspect between 8 am and 10 am homeowners name is Glenn Pearce Phone #: ###-#### Inspection requested via web by Marisa Hone