ELE17-02390
| Final | 12/18/2017 | 12/19/2017 | 12/19/2017 2:03:40 PM | P | PART |
|
|
Call Doug 30 min prior. Partial final on 16 S side apartments. Will do N side on 12/20/17, a long with gazebo that is fed from house panel at 7364 Bldg D.
|
ELE17-03892
| Final | 12/18/2017 | 12/19/2017 | 12/19/2017 1:57:30 PM | A | PASS |
|
|
Pls contact Barry (Electrician) @ ###-#### one hr prior or if you have any questions. The left side gate is open which lends access to back yard. Thank you. Inspection requested via web by Christian Kilpatrick Ok final.
|
ELE17-03404
| Conference | 12/19/2017 | 12/19/2017 | 12/19/2017 1:52:51 PM | P | PASS |
|
|
do you want to see the soffit protection?,, Tony #415 Ok cover soffit. I talked to Tony and he sent pics also.
|
ELE17-04256
| Rough-In Permanent Service | 12/19/2017 | 12/19/2017 | 12/19/2017 12:22:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Rohl p/s u/g n ok
|
ELE17-04262
| Rough-In Permanent Service | 12/19/2017 | 12/19/2017 | 12/19/2017 12:09:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Paula Gratiot p/s u/g n ok
|
ELE17-03865
| Electrical Rough-In | 12/14/2017 | 12/19/2017 | 12/19/2017 12:08:51 PM | P | PASS |
|
|
Brandy Phone #: ###-#### Ok cover. All components UL listed.
|
ELE17-04044
| Electrical Rough-In | 12/18/2017 | 12/19/2017 | 12/19/2017 10:48:49 AM | A | PASS |
|
|
Rough in inspection Please contact Darren Hoff 30 minutes before inspection to gain access to home 208.807.5122 Phone #: ###-#### Inspection requested via web by David Feller Ok cover kitchen and upstairs
|
ELE17-04251
| Rough-In Permanent Service | 12/18/2017 | 12/19/2017 | 12/19/2017 10:25:59 AM | A | PASS |
|
|
Dan Phone #: ###-#### Inspection requested via web by Dan Hobdey p/s u/g n ok
|
ELE17-04249
| Electrical Rough-In | 12/18/2017 | 12/19/2017 | 12/19/2017 10:10:04 AM | A | PASS |
|
|
Listing inspection for panels and optimizers. Approved plans onsite. Rooftop install crew onsite. Phone #: ###-#### Inspection requested via web by Ryan King Ok cover. Installer was on site with all paperwork needed. All components UL listed.
|
ELE17-04238
| Final | 12/18/2017 | 12/19/2017 | 12/19/2017 10:01:25 AM | A | PASS |
|
|
Rewiring of first and second floor of home. Surface mount wire mold was used in some places. Exposed conduit on exterior. AFCI used in bedrooms and smokes. Call with any questions. Phone #: ###-#### Inspection requested via web by Garrett Collins Ok final
|
ELE17-02733
| Rough-In Permanent Service | 12/18/2017 | 12/19/2017 | 12/19/2017 9:48:04 AM | A | FAIL |
|
|
Call john if any problems Phone #: ###-#### Inspection requested via web by John Harvey 2" conduit is not a full run to panel in basement. THHN is laying on floor of crawl space. Either continue conduit completely to basement panel, or pull SER to feed panel.
|
ELE17-03032
| Electrical Rough-In | 12/19/2017 | 12/19/2017 | 12/19/2017 9:22:36 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by steve sellers Inspection cancelled from web by: steve sellers
|