Inspections for the day of: Wednesday, December 19, 2018.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-04637 Electrical Rough-In12/19/201812/19/201812/19/2018 4:13:45 PMPPASS
R/I inspection spinning room area 2. Call Bobby, thanks. Phone #: ###-#### Inspection requested via web by Rafael Castillo Spinning room ceiling only ok to cover
ELE18-04719 Temporary Service12/19/201812/19/201812/19/2018 12:47:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE18-04771 Electrical Rough-In12/18/201812/19/201812/19/2018 12:13:54 PMAPASS
For access please call Jaman 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott main bath and up master bath rough in ok
ELE11-01976 Final12/18/201812/19/201812/19/2018 11:33:42 AMAPASS
For access please call Jaman 1/2 hr prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Terry Scott Final ok
ELE18-03635 Final12/14/201812/19/201812/19/2018 11:27:24 AMAFAIL
There will be someone home. If you have any questions please feel free to contact Andrew ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan AFCI breaker installed instead of GFCI for garage feed. Missing KO seal in bottom of panel. Mislabeled panel schedule. Slip joint installed upside down.
ELE18-03420 Final12/18/201812/19/201812/19/2018 10:35:55 AMAPASS
garage code 1624 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
ELE18-03526 Final12/18/201812/19/201812/19/2018 10:35:32 AMAPASS
garage code 1824 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
ELE18-03538 Final12/18/201812/19/201812/19/2018 10:35:05 AMAFAIL
garage code 1724 Phone #: ###-#### Inspection requested via web by Darryn Coburn Max overcurrent on A/C nameplate is 20A(30A installed) Missing panel cover screws. Garage receps showing Hot/Ground reverse while GFCI recep tripped.
ELE18-04734 Rough-In Permanent Service12/18/201812/19/201812/19/2018 9:50:16 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
ELE18-04637 Electrical Rough-In12/19/201812/19/201812/19/2018 9:30:50 AMAPART
Please call Bobby for inspection of ceiling in area C 1st floor and grid ceiling on 2nd floor. Phone #: ###-#### Inspection requested via web by Rafael Castillo 2nd floor area C minus Spinning room 202. 1st floor restrooms area C Ceilings only ok to cover