Inspections for the day of: Wednesday, December 19, 2018.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03087 Rough-in12/18/201812/19/201812/19/2018 4:10:35 PMPPASS
Tom Phone #: ###-####
2- 100lb hydronics pressure test ok
- 20lb gas pressure test ok
MIS18-00469 MEC-Conference12/19/201812/19/201812/19/2018 3:39:06 PMPPASS
Eli Phone #: ###-####
- mech ok
- signed card for occ
MEC18-04729 Final12/19/201812/19/201812/19/2018 3:24:03 PMPPART
Joe Phone #: ###-####
- still need to see c02 sensors installed and interlocked with exhausts and make up air dampers
MIS18-00462 MEC-Conference12/19/201812/19/201812/19/2018 3:08:26 PMPDONE
christian Phone #: ###-####
- talked with general contractor about pedicure exhaust and nail station exhaust needs to be per eng. plans that have been approved by the city
MEC18-05751 Final12/17/201812/19/201812/19/2018 2:16:35 PMPFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- need to see a wet switch in the drain pan under the furnace
- electrical wiring is touching the b vent for the furnace
MEC18-05588 Final12/19/201812/19/201812/19/2018 1:55:30 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- air handler only co ok
MEC18-04598 Final12/18/201812/19/201812/19/2018 1:33:37 PMPPASS
AC:1305 Phone #: ###-#### Inspection requested via web by Gary Reeves
- final ok
MEC18-05779 Rough-in12/18/201812/19/201812/19/2018 11:23:57 AMAPART
Hard lid cover inspection thank you. Phone #: ###-#### Inspection requested via web by RaChelle Frisbee
- exhaust fan/ supply runs ok
- hard lid cover in bathrooms only ok
MEC18-05997 Pressure Test12/18/201812/19/201812/19/2018 10:35:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Justin Osterhout
- 20lb gas pressure test ok
- make sure to seal gas line penetration
- tagged new gas line
MEC18-05233 Final12/18/201812/19/201812/19/2018 10:15:32 AMAPASS
Home owners will be there Inspection requested via web by jeff jedlick
- fireplace final ok
MEC18-06031 Rough-in12/19/201812/19/201812/19/2018 9:56:33 AMAPASS
Please call Tony Koonce with any questions Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- fireplace R/I ok
MEC18-05544 Final12/13/201812/19/201812/19/2018 9:40:28 AMAFAIL
Please call client prior to arrival at ###-####
Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- reflectix duct insulation needs spacers in place for air gap
- secondary drains needs either a wet switch or ran to garage floor
MEC18-05804 Final12/17/201812/19/201812/19/2018 9:15:47 AMAFAIL
If possible please call Lori at ###-#### one hour before. Thank you. Phone #: ###-#### Inspection requested via web by James Cox
-A/C breaker size needs to be a 25 amp
- need approved furnace disconnect
- secondary drain needs a wet switch right now its draining on carpet
- single wall pipe needs 6" clearances/ reduction methods applied or b vent installed
MEC18-04154 Conference12/18/201812/19/201812/19/2018 8:45:32 AMACANC
late a.m. with Dustin ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- cancelled this will be rescheduled for tomorrow morning
MEC18-03016 Final12/18/201812/19/201812/19/2018 8:34:14 AMAPASS
Mike Phone #: ###-####
final ok
MEC17-05632 Mec-Aging Inspection12/19/201812/19/201812/19/2018 8:03:50 AM DONE
called A-1 and talked with Shawn about aging permit
MEC18-01254 Mec-Aging Inspection12/19/201812/19/201812/19/2018 8:00:51 AM PASS
MEC18-01254 DOC - Permit Finaled12/19/201812/19/201812/19/2018 8:00:42 AMPPASS
MEC18-05932 Final12/14/201812/19/201812/17/2018 12:10:52 PMACANC
Please call customer prior to arrival - Paula ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks