Inspections for the day of: Thursday, December 19, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04864 Final12/18/201912/19/201912/19/2019 4:54:52 PMPNR
Contact: Matt Cinko... service and final inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden Not ready. Need inspection after re-energized
ELE19-04864 Final12/19/201912/19/201912/19/2019 4:54:41 PMPPASS
Contact: Matt Cinko... service and final inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden Existing solar needs to be landed at opposite end of bussing from main breaker. Mast is over 30in above roof line and will need guy wire installed. p/s o/h rec ok
ELE19-02930 Final12/19/201912/19/201912/19/2019 1:55:46 PMPPASS
Phone #: ###-#### Inspection requested via web by Zane Robertson final ok
ELE19-04865 Final12/18/201912/19/201912/19/2019 12:56:15 PMPNH
wiring for new gas furnace Phone #: ###-#### Inspection requested via web by Emmet Bushman No access Re-call final.
ELE19-04871 Electrical Rough-In12/19/201912/19/201912/19/2019 12:12:22 PMPPASS
Access to shop is in the alley Phone #: ###-#### Inspection requested via web by Jay Symonds Garage only ok to cover
ELE19-04852 Final12/19/201912/19/201912/19/2019 12:05:33 PMPPASS
Homeowner will be on site to let you in to look at the panel if you need to thank you have a great day Phone #: ###-#### Inspection requested via web by TRENT Swaim final ok
ELE19-03820 Final12/19/201912/19/201912/19/2019 11:56:52 AMANR
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Not ready. Missing coach lights
ELE19-04676 Permanent Service12/19/201912/19/201912/19/2019 11:32:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn p/s u/g n ok
ELE19-02181 Electrical Rough-In12/18/201912/19/201912/19/2019 11:21:28 AMAPASS
Inspect = Transferred switch legs for lights, from the attic to the newly installed
garage/dining door.
Installed a j-box to extend a circuit, for newly installed windows.

Thank you,
Phone #: ###-#### Inspection requested via web by Lonnie Sorichta rough in ok
ELE19-04443 Final12/18/201912/19/201912/19/2019 11:20:26 AMAPASS
Homeowner will be on-site all day Phone #: ###-#### Inspection requested via web by Ashley Lanham 20A breaker installed on a 200A Panelboard. Breaker was installed in Middle of busing at time of inspection. 705.12B2(3)(b). 40 amp max when installed at opposite ends of busing. (Breaker may not be upsized unless relocated in panel) Final ok
ELE19-04816 Electrical Rough-In12/18/201912/19/201912/19/2019 10:07:06 AMAPASS
Underground ; bonding for swimming pool Phone #: ###-#### Inspection requested via web by Lars Johnson Underground and corner bond ok to cover