ELE08-00234
| ELE-Aging Inspection | 12/2/2008 | 12/2/2008 | 12/5/2008 10:16:50 AM | | DONE |
|
|
looked for sign, none installed or changed
|
ELE08-00270
| ELE-Aging Inspection | 12/2/2008 | 12/2/2008 | 12/5/2008 10:14:18 AM | | DONE |
|
|
called, left message to call for final inspection, no esc this project
|
ELE08-02747
| Final | 12/2/2008 | 12/2/2008 | 12/2/2008 4:32:31 PM | P | NR |
|
|
michelle Phone #: ###-#### called corrections not done
|
ELE08-00242
| ELE-Aging Inspection | 12/2/2008 | 12/2/2008 | 12/2/2008 3:30:32 PM | | DONE |
|
|
ok to final, see final, no esc this project
|
ELE08-00242
| Final | 12/2/2008 | 12/2/2008 | 12/2/2008 3:29:56 PM | P | PASS |
|
|
ok to final, no esc this project
|
ESC08-00679
| Site Final | 12/2/2008 | 12/2/2008 | 12/2/2008 3:20:25 PM | P | PASS |
|
|
looked ok, ok to final
|
ESC08-00330
| General Inspection | 12/2/2008 | 12/2/2008 | 12/2/2008 3:18:17 PM | A | PASS |
|
|
looked ok, trash in truck
|
ESC08-00512
| General Inspection | 12/2/2008 | 12/2/2008 | 12/2/2008 3:16:34 PM | A | PASS |
|
|
looked ok
|
ESC07-01432
| General Inspection | 12/2/2008 | 12/2/2008 | 12/2/2008 3:15:31 PM | A | PASS |
|
|
looked ok
|
ELE08-02849
| Final | 12/2/2008 | 12/2/2008 | 12/2/2008 3:14:30 PM | P | PASS |
|
|
sprikler time clock is located in the island at the entrance off Overland Rd. Phone #: ###-#### Internet Inspection Request from: gary batten ok to final, no esc this project
|
ELE08-03124
| Electrical Rough-In | 12/2/2008 | 12/2/2008 | 12/2/2008 2:50:21 PM | P | PASS |
|
|
contact: Bob Schroder ** Late PM if possible. ** ***** Please call before going to job so Bob can meet you there. Thx! ***** Phone #: ###-#### Internet Inspection Request from: Julie Schroder ok to cover walls and ceilings, no esc this project
|
ELE08-02393
| Final | 12/2/2008 | 12/2/2008 | 12/2/2008 1:43:57 PM | P | PASS |
|
|
andy Note: please call 10 minutes prior to inspection Phone #: ###-#### met owner ok to final, no esc this project
|
ELE08-02531
| Final | 12/2/2008 | 12/2/2008 | 12/2/2008 12:42:46 PM | P | PASS |
|
|
Request Final inspection - Loren Ramsey Phone #: ###-#### Internet Inspection Request from: Kevin Perez called contractor, ok to final
|
ELE08-02423
| Electrical Rough-In | 12/1/2008 | 12/2/2008 | 12/2/2008 10:31:33 AM | A | PASS |
|
|
JASON CEILING COVER B3 L1 UNITS B1, D, D1 Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok to cover ceilings only anop- 3 umits
|
ELE08-02120
| Final | 12/1/2008 | 12/2/2008 | 12/2/2008 9:42:45 AM | A | PASS |
|
|
Chris is the onsite contact, his no. is ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Shawna Gates met contractor, ok to final, signed occupaqncy card
|
ELE08-02747
| Final | 12/1/2008 | 12/2/2008 | 12/2/2008 8:59:41 AM | P | FAIL |
|
|
Michelle Phone #: ###-#### called, left correction notice, NEC 348.12(1) fmc shall not be used in wet locations and conductors must be suitable for wet locations, 210.52(D) shall install gfci protected receptacle within 3' of bath basin, 210.11(C)(3) there shall be no other outlets on bath circuit, 110.3(B) listed equipment shall be installed and used in accordance with labels and operate- garage entry area, 314.21 shall repair all drywall around boxes- less than 1/8" gap at u/c lights and range receptacle, 410.16(C) shall provide minimum 12" from edge of storage space to edge of fixture in clothes closet- master bed room, 680.73 tub access shall be per manufacturers instructions and accessible without removing screws or other permanent finish, 250.94 intersystem bonding terminination shall be provided
|