Inspections for the day of: Tuesday, December 2, 2008.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00234 ELE-Aging Inspection12/2/200812/2/200812/5/2008 10:16:50 AM DONE
looked for sign, none installed or changed
ELE08-00270 ELE-Aging Inspection12/2/200812/2/200812/5/2008 10:14:18 AM DONE
called, left message to call for final inspection, no esc this project
ELE08-02747 Final12/2/200812/2/200812/2/2008 4:32:31 PMPNR
michelle Phone #: ###-#### called corrections not done
ELE08-00242 ELE-Aging Inspection12/2/200812/2/200812/2/2008 3:30:32 PM DONE
ok to final, see final, no esc this project
ELE08-00242 Final12/2/200812/2/200812/2/2008 3:29:56 PMPPASS
ok to final, no esc this project
ESC08-00679 Site Final12/2/200812/2/200812/2/2008 3:20:25 PMPPASS
looked ok, ok to final
ESC08-00330 General Inspection12/2/200812/2/200812/2/2008 3:18:17 PMAPASS
looked ok, trash in truck
ESC08-00512 General Inspection12/2/200812/2/200812/2/2008 3:16:34 PMAPASS
looked ok
ESC07-01432 General Inspection12/2/200812/2/200812/2/2008 3:15:31 PMAPASS
looked ok
ELE08-02849 Final12/2/200812/2/200812/2/2008 3:14:30 PMPPASS
sprikler time clock is located in the island at the entrance off Overland Rd. Phone #: ###-#### Internet Inspection Request from: gary batten ok to final, no esc this project
ELE08-03124 Electrical Rough-In12/2/200812/2/200812/2/2008 2:50:21 PMPPASS
contact: Bob Schroder ** Late PM if possible. **
***** Please call before going to job so Bob can meet you there. Thx! ***** Phone #: ###-#### Internet Inspection Request from: Julie Schroder ok to cover walls and ceilings, no esc this project
ELE08-02393 Final12/2/200812/2/200812/2/2008 1:43:57 PMPPASS
andy Note: please call 10 minutes prior to inspection Phone #: ###-#### met owner ok to final, no esc this project
ELE08-02531 Final12/2/200812/2/200812/2/2008 12:42:46 PMPPASS
Request Final inspection - Loren Ramsey Phone #: ###-#### Internet Inspection Request from: Kevin Perez called contractor, ok to final
ELE08-02423 Electrical Rough-In12/1/200812/2/200812/2/2008 10:31:33 AMAPASS
JASON CEILING COVER B3 L1 UNITS B1, D, D1 Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok to cover ceilings only anop- 3 umits
ELE08-02120 Final12/1/200812/2/200812/2/2008 9:42:45 AMAPASS
Chris is the onsite contact, his no. is ###-####. Thank you. Phone #: ###-#### Internet Inspection Request from: Shawna Gates met contractor, ok to final, signed occupaqncy card
ELE08-02747 Final12/1/200812/2/200812/2/2008 8:59:41 AMPFAIL
Michelle Phone #: ###-#### called, left correction notice, NEC 348.12(1) fmc shall not be used in wet locations and conductors must be suitable for wet locations, 210.52(D) shall install gfci protected receptacle within 3' of bath basin, 210.11(C)(3) there shall be no other outlets on bath circuit, 110.3(B) listed equipment shall be installed and used in accordance with labels and operate- garage entry area, 314.21 shall repair all drywall around boxes- less than 1/8" gap at u/c lights and range receptacle, 410.16(C) shall provide minimum 12" from edge of storage space to edge of fixture in clothes closet- master bed room, 680.73 tub access shall be per manufacturers instructions and accessible without removing screws or other permanent finish, 250.94 intersystem bonding terminination shall be provided