Inspections for the day of: Friday, December 2, 2011.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-00477 ELE-Aging Inspection12/2/201112/2/201112/2/2011 2:57:15 PM DONE
see final
ELE11-00477 Final12/2/201112/2/201112/2/2011 2:57:03 PMPPASS
ok final
ELE11-02590 Final12/2/201112/2/201112/2/2011 2:55:41 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Tyler Bowen per conversation with contractor at ri, ok final
ELE11-02108 Electrical Rough-In12/2/201112/2/201112/2/2011 2:52:15 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Debby Ellis ri ok anop
ELE11-01951 Electrical Rough-In12/2/201112/2/201112/2/2011 1:56:06 PMPFAIL
Contact: Brian Gee - basement walls roughin please Phone #: ###-#### >> Inspection requested via web by Deb Gooden called, check depth panel clearance, tie-wraps not approved for nm support, will fix and re-call
ELE11-02701 Rough-In Permanent Service12/2/201112/2/201112/2/2011 1:26:01 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Kathy Smith ri ok, p/s, exst meter pak, n, ok
ELE11-02026 Final12/2/201112/2/201112/2/2011 12:56:44 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Rick Beckman called, left correction notice, NEC 344.30 shall securely support riser within 3' of panel, 250.94 shall provide intersystem bond bar, 210.52(A)(2) shall provide outlet in 2' wall space under bar type counter, 406.4 shall securely mount receptacles
ELE11-02358 Electrical Rough-In12/1/201112/2/201112/2/2011 11:36:04 AMAPASS
garage code is 2502 Phone #: ###-#### >> Inspection requested via web by cal crosby tub ok, found labels
ELE11-00557 Rough-In Permanent Service12/1/201112/2/201112/2/2011 10:35:16 AMAPASS
Contact is Deeon Martineau-he states that this will be a long inspection tomorrow, just a heads up Phone #: ###-#### >> Inspection requested via web by Scott Campbell ri ok anop, ok p/s for power as needed
ELE11-02632 Rough-In Permanent Service12/1/201112/2/201112/2/2011 8:49:37 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
ELE11-02701 Electrical Rough-In12/1/201112/2/201112/2/2011 8:30:33 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Kathy Smith walls only ok cover, told contractor no power until addressing documented
ELE11-02569 Final12/1/201112/2/201112/2/2011 8:09:27 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Cyndi Dale called, initialled correction notice for parts corrected, shall leave ceiling tiles out for inspection
ELE11-02358 Conference12/1/201112/2/201112/1/2011 2:28:54 PMACANC
garage code 2502 Phone #: ###-#### >> Inspection requested via web by cal crosby Inspection cancelled from web by: cal crosby