ELE12-01275
| ELE-Aging Inspection | 12/2/2013 | 12/2/2013 | 12/9/2013 10:31:15 AM | | CANC |
|
|
|
ELE13-03311
| Final | 12/2/2013 | 12/2/2013 | 12/2/2013 4:33:19 PM | P | PART |
|
|
>> Inspection requested via web by Terry Scott ok cover u/g
|
ELE13-03184
| Final | 12/2/2013 | 12/2/2013 | 12/2/2013 2:09:12 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Rohl ok final, signed card
|
ELE13-02430
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 1:53:37 PM | P | PASS |
|
|
Rough inspection of new interior wall in the warehouse area. Contact is Nathan Cornell. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery ok cover wall
|
ELE13-02358
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 1:22:28 PM | P | PART |
|
|
East wall only Phone #: ###-#### >> Inspection requested via web by Bryan Atkins ok cover east wall in office area, 1st floor only
|
ELE13-02772
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 1:05:49 PM | P | PASS |
|
|
Electrical rough in on master bathroom heated tile floor Phone #: ###-#### >> Inspection requested via web by Rhonda Zamagni called and told electrician to ensure room count 15 rooms, not 7, ok cover floor heat
|
ELE13-03340
| Final | 12/2/2013 | 12/2/2013 | 12/2/2013 12:21:13 PM | P | PASS |
|
|
Fix power to shed that has furnace and A/C unit Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes ok final
|
ELE13-03340
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 11:46:56 AM | P | PASS |
|
|
Fix power to shed that has furnace and A/C unit Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes ri ok
|
ELE11-01478
| ELE-Aging Inspection | 12/2/2013 | 12/2/2013 | 12/2/2013 10:10:10 AM | | DONE |
|
|
still under construction
|
ELE13-03064
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 9:53:02 AM | A | PASS |
|
|
Home owner will be there. Kitchen area Phone #: ###-#### >> Inspection requested via web by Mike Cole ri kitchen ok
|
ELE13-02846
| Electrical Rough-In | 11/30/2013 | 12/2/2013 | 12/2/2013 9:00:54 AM | A | FAIL |
|
|
Should be open for ceiling inspection. Phone #: ###-#### >> Inspection requested via web by Lynn Cable called, left correction notice, BCC no violations shall be retained, 725.25 shall remove abandoned cables, 300.11(B) raceways shall not be used as support for other raceways unless identified for purpose, 300.11(A) shall not support cable by grid or tile, 330.30(B) mc shall be secured within 12" of box, 314.23(E) raceways shall not support box, 314. 25 boxes shall be closed, 314.7(B) shall provide abrasion protection for conductors in metal boxes
|