ELE10-01304
| ELE-Aging Inspection | 12/2/2013 | 12/2/2013 | 12/2/2013 4:40:04 PM | | DONE |
|
|
still under construction
|
ELE12-01245
| Final | 12/2/2013 | 12/2/2013 | 12/2/2013 3:48:20 PM | P | PASS |
|
|
job complete, final ok
|
ELE13-03306
| Rough-In Permanent Service | 12/2/2013 | 12/2/2013 | 12/2/2013 2:30:42 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Duplicate rough-in p/s u/g rec ok
|
ELE13-03306
| Rough-In Permanent Service | 12/2/2013 | 12/2/2013 | 12/2/2013 2:26:44 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov corrections done, rough-in p/s u/g rec ok
|
ELE13-02786
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 2:09:44 PM | P | PASS |
|
|
Requesting a partial rough in inspection. Phone #: ###-#### >> Inspection requested via web by Dan Hardisty 3 recessed cans in hard lid, rough-in ok cover
|
ELE13-03325
| Permanent Service | 12/2/2013 | 12/2/2013 | 12/2/2013 2:01:17 PM | P | FAIL |
|
|
Tim Phone #: ###-#### NEC 250.52 The electrodes shall be installed such that at least 8ft. of the lenght is in contact with the soil. NEC 250.53(C) Bonding jumper NEC 300.4 NM cable Protection fron phyical damage, not less than 1 1/4 from edge of framing member NEC 334.30 NM cable shall be secured within 12 in. of panel
|
ELE13-03181
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 12:54:24 PM | P | FAIL |
|
|
Mike Anderson Phone #: ###-#### NEC 330 .12(1) Subject to phyical damage, Less Than 1 1/4 to edge framing member. NEC 330.30 Securing MC cable with-in 12in. of box. Receptacle box requiring ko plugs
|
ELE13-01797
| Electrical Rough-In | 11/27/2013 | 12/2/2013 | 12/2/2013 12:19:03 PM | P | NR |
|
|
Ceiling inspection, Geoff Hannaford is contact, ###-#### Phone #: ###-#### >> Inspection requested via web by Debby Ellis Not ready
|
ELE13-02876
| Final | 12/2/2013 | 12/2/2013 | 12/2/2013 12:07:27 PM | P | FAIL |
|
|
Arcade area outlets. Please call Kyle @ ###-#### with questions. Phone #: ###-#### >> Inspection requested via web by Amie Rose Vending machines in place,not able to test receptacles
|
ELE13-02876
| Electrical Rough-In | 12/2/2013 | 12/2/2013 | 12/2/2013 12:03:08 PM | P | FAIL |
|
|
Outlets in Arcade area. Please call Kyle @ ###-#### with questions. Phone #: ###-#### >> Inspection requested via web by Amie Rose Vending machines in place, not able to test receptacles
|
ELE13-03331
| Rough-In Permanent Service | 11/27/2013 | 12/2/2013 | 12/2/2013 9:57:51 AM | A | PASS |
|
|
call first Phone #: ###-#### >> Inspection requested via web by PAT MILLER Service upgrade rough-in p/s u/g rec ok
|
ELE13-03306
| Rough-In Permanent Service | 12/2/2013 | 12/2/2013 | 12/2/2013 9:32:29 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov NEC 250 Requires service to be connected to concrete encased electrode. NEC 210.52(H) Hallways over 10ft. Require a receptacle
|
ELE13-03339
| Temporary Service | 12/1/2013 | 12/2/2013 | 12/2/2013 8:33:35 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey t/s u/g n ok
|
ELE13-03337
| Electrical Rough-In | 12/1/2013 | 12/2/2013 | 12/2/2013 8:23:23 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jerry Moore rough-in ok cover front entry sun room
|