Inspections for the day of: Monday, December 20, 2004.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-03667 Electrical Rough-In12/20/200412/20/200412/20/2004 12:00:00 AM DONE
ok 12/20/2004 5:17:14 PM
ELE04-03994 Temporary Service12/17/200412/20/200412/20/2004 12:00:00 AMAPASS
###-#### allan called clean t/s and drive grd rod flush t/s u/g new ok 12/20/2004 9:31:46 AM
ELE04-03759 Final12/17/200412/20/200412/20/2004 12:00:00 AMAPASS
Bill; Phone #: ###-#### Internet Inspection Request from: Jan Rice ok card signed 12/20/2004 8:54:33 AM
ELE04-03981 Electrical Rough-In12/17/200412/20/200412/20/2004 12:00:00 AMAPART
Doug; Phone #: ###-#### Internet Inspection Request from: Jan Rice walls ok called before final needs show window outlets installed 12/20/2004 9:13:21 AM
ELE04-04000 Electrical Rough-In12/17/200412/20/200412/20/2004 12:00:00 AMAPART
cor. posted uncover all u/g covered before inspection, garage walls and ceilings ok for cover 12/20/2004 10:04:18 AM
ELE04-04000 Final12/17/200412/20/200412/20/2004 12:00:00 AMAFAIL
Roger; Phone #: ###-#### Internet Inspection Request from: Jan Rice cor. posted called shall protect romex, or install sheetrock,334.15, and install all outside fixtures also uncover u/g covered before inspection 12/20/2004 10:06:21 AM
ELE04-02595 Electrical Rough-In12/17/200412/20/200412/20/2004 12:00:00 AMACANC
Scheduled by a contractor via Hello! on 12/17/2004 at 2:41:54 PM. Contact: ###-####. contractor is checking on outlet requirements for room 210.60, quest rooms does not have required recept outlets 12/20/2004 10:51:09 AM
ELE04-03704 Final12/17/200412/20/200412/20/2004 12:00:00 AMANH
dan ; Phone #: ###-####8 Internet Inspection Request from: Marsha Smylie no access 12/20/2004 10:36:30 AM
ELE04-03982 Permanent Service12/19/200412/20/200412/20/2004 12:00:00 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Jim Williams needs 2 grd rods size bonding to 250.66, remove sprinkler equip from below p/s
p/s u/g rec. ok 12/20/2004 8:28:52 AM
ELE04-04009 Final12/20/200412/20/200412/20/2004 12:00:00 AMPPASS
###-#### - roy ok 12/20/2004 12:25:34 PM
ELE04-03146 Electrical Rough-In12/20/200412/20/200412/20/2004 12:00:00 AMPNR
butch; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie contractor called and canceled 12/20/2004 2:21:32 PM
ELE04-03916 Electrical Rough-In12/20/200412/20/200412/20/2004 12:00:00 AMPPASS
butch; Phone #: ###-#### Note: Please late afternoon Internet Inspection Request from: Marsha Smylie ok 12/20/2004 5:03:25 PM
ELE04-03927 Final12/20/200412/20/200412/20/2004 12:00:00 AMPPASS
PLEASE CONTACT TOM GILBERT. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: Wendy Waters ok card signed 12/20/2004 2:20:59 PM
ELE04-01954 Electrical Rough-In12/20/200412/20/200412/20/2004 12:00:00 AMPFAIL
amy or josh; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. posted met owner 300.4, 200.6, shall ID,or use white as phase, 314.20 outside boxes flush, 250.24 install bond screw, 250.52(A)(1),104(A)(1) grd or bond water pipe, 210.52(A) outlet spacing, 210.11(C) laundry circuit, 210.52(D) outlet within 3ft of sink,250.140 needs insulated neutral to range, shall install concrete encased electrode,314.17(C) replace 2gang box broken clamp,310.15 derate conductors in 2" pvc,230.28 support p/s mast 12/20/2004 5:03:15 PM
ELE04-03925 Rough-In Permanent Service12/20/200412/20/200412/20/2004 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 12/20/2004 at 10:49:28 AM. Contact: ###-####. ok p/s o/h rec. 12/20/2004 12:52:41 PM
ELE04-03903 Final12/20/200412/20/200412/20/2004 12:00:00 AMPNH
Dave; Phone #: ###-#### Internet Inspection Request from: Jan Rice notice posted called 12/20/2004 4:53:50 PM
ELE04-04009 Permanent Service12/20/200412/20/200412/20/2004 12:00:00 AMPPASS
p/s u/g rec.
ELE04-03667 Electrical Rough-In12/20/200412/20/200412/20/2004 12:00:00 AMPPASS
ok corrections made 12/20/2004 1:26:39 PM
ELE04-04005 Final12/17/200412/20/200412/20/2004 12:00:00 AMPFAIL
Phone #: ###-#### Internet Inspection Request from: Dana Moyer cor. posted called 314.27(C) shall provide listed floor box and cover for floor outlet 12/20/2004 1:58:08 PM