ELE11-02847
| Electrical Rough-In | 12/20/2011 | 12/20/2011 | 12/20/2011 3:24:18 PM | P | PASS |
|
|
Rough in on kitchen remodel this is building #205 Phone #: ###-#### >> Inspection requested via web by Emmet Bushman ri ok
|
ELE11-02818
| Electrical Rough-In | 12/19/2011 | 12/20/2011 | 12/20/2011 3:13:10 PM | P | PASS |
|
|
contact mike cole ###-#### trench inspection be ready right after lunch Phone #: ###-#### >> Inspection requested via web by Eric Brown north part u/g ok cover anop
|
ELE11-02829
| Temporary Service | 12/20/2011 | 12/20/2011 | 12/20/2011 2:24:12 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson corrections made, t/s u/g n ok
|
ELE11-02850
| Electrical Rough-In | 12/20/2011 | 12/20/2011 | 12/20/2011 1:47:47 PM | P | PASS |
|
|
Rim Crest Condos Phone #: ###-#### >> Inspection requested via web by Julie Schroder ri ok
|
ELE11-02621
| Final | 12/15/2011 | 12/20/2011 | 12/20/2011 12:54:11 PM | P | FAIL |
|
|
Someone will be home. any ?''s or concerns call Clay at ###-####> Thx >> Inspection requested via web by Clay Morgan called, left message, shall fix open ground in closet outlet, install outside outlet, and lights
|
ELE11-02231
| Final | 12/20/2011 | 12/20/2011 | 12/20/2011 12:15:11 PM | P | PASS |
|
|
call for access---Neil Phone #: ###-#### corrections made, ok final
|
ELE08-00828
| Final | 12/19/2011 | 12/20/2011 | 12/20/2011 10:49:39 AM | A | FAIL |
|
|
Sean. Please call prior to heading to site. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy corrections not made
|
ELE08-00318
| Final | 12/19/2011 | 12/20/2011 | 12/20/2011 10:42:34 AM | A | FAIL |
|
|
Sean. Please call prior to heading to site. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy corrections not made
|
ELE11-02772
| Electrical Rough-In | 12/19/2011 | 12/20/2011 | 12/20/2011 9:58:32 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by John VanZandt called, left correction notice, NEC 300.4(A)(D) edge of bored holes, nm, raceways shall be 1 1/4" from edge of framing members, 342.46 shall provide bushing for fmc, 314.17(C) shall staple nm within 8" of box, 334.30 shall not staple nm on edge, 334.80 shall derate nm if over 2 cables in hole, 250.86 shall ground metal boxes, BCC all make-up shall be done, boxes installed, wire boxes, prepare interface for old wall, check into 2' wall space for outlets top of stairs
|
ELE11-01951
| Electrical Rough-In | 12/19/2011 | 12/20/2011 | 12/20/2011 8:53:16 AM | A | PASS |
|
|
Contact: Brian Gee - rough in wall for cover please. Phone #: ###-#### >> Inspection requested via web by Deb Gooden ri ok, left correction notice,NEC 110.26 shall provide workspace about panel before final
|
ELE11-02383
| Final | 12/19/2011 | 12/20/2011 | 12/20/2011 8:20:21 AM | A | PASS |
|
|
Calvin Phone #: ###-#### ok final
|