Inspections for the day of: Tuesday, December 20, 2011.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02847 Electrical Rough-In12/20/201112/20/201112/20/2011 3:24:18 PMPPASS
Rough in on kitchen remodel this is building #205 Phone #: ###-#### >> Inspection requested via web by Emmet Bushman ri ok
ELE11-02818 Electrical Rough-In12/19/201112/20/201112/20/2011 3:13:10 PMPPASS
contact mike cole ###-#### trench inspection be ready right after lunch Phone #: ###-#### >> Inspection requested via web by Eric Brown north part u/g ok cover anop
ELE11-02829 Temporary Service12/20/201112/20/201112/20/2011 2:24:12 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson corrections made, t/s u/g n ok
ELE11-02850 Electrical Rough-In12/20/201112/20/201112/20/2011 1:47:47 PMPPASS
Rim Crest Condos Phone #: ###-#### >> Inspection requested via web by Julie Schroder ri ok
ELE11-02621 Final12/15/201112/20/201112/20/2011 12:54:11 PMPFAIL
Someone will be home. any ?''s or concerns call Clay at ###-####> Thx >> Inspection requested via web by Clay Morgan called, left message, shall fix open ground in closet outlet, install outside outlet, and lights
ELE11-02231 Final12/20/201112/20/201112/20/2011 12:15:11 PMPPASS
call for access---Neil Phone #: ###-#### corrections made, ok final
ELE08-00828 Final12/19/201112/20/201112/20/2011 10:49:39 AMAFAIL
Sean. Please call prior to heading to site. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy corrections not made
ELE08-00318 Final12/19/201112/20/201112/20/2011 10:42:34 AMAFAIL
Sean. Please call prior to heading to site. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy corrections not made
ELE11-02772 Electrical Rough-In12/19/201112/20/201112/20/2011 9:58:32 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by John VanZandt called, left correction notice, NEC 300.4(A)(D) edge of bored holes, nm, raceways shall be 1 1/4" from edge of framing members, 342.46 shall provide bushing for fmc, 314.17(C) shall staple nm within 8" of box, 334.30 shall not staple nm on edge, 334.80 shall derate nm if over 2 cables in hole, 250.86 shall ground metal boxes, BCC all make-up shall be done, boxes installed, wire boxes, prepare interface for old wall, check into 2' wall space for outlets top of stairs
ELE11-01951 Electrical Rough-In12/19/201112/20/201112/20/2011 8:53:16 AMAPASS
Contact: Brian Gee - rough in wall for cover please. Phone #: ###-#### >> Inspection requested via web by Deb Gooden ri ok, left correction notice,NEC 110.26 shall provide workspace about panel before final
ELE11-02383 Final12/19/201112/20/201112/20/2011 8:20:21 AMAPASS
Calvin Phone #: ###-#### ok final