ELE13-02945
| Final | 12/19/2016 | 12/20/2016 | 12/20/2016 1:54:10 PM | P | FAIL |
|
|
Matt Phone #: ###-####-please call with a meet time Homeowner covered with drywall prior to approval. Only items unable to confirm completed are NM abrasion protection and securing near boxes. After asking owner questions of how he completed corrections I believe them to be completed. 110.3- Fittings for EMT installed on water heater shall be listed for EMT. 422.30- A disconnecting means shall be installed on water heater circuit. 110.25 lockout acceptable. Complete and call for final
|
ELE16-00489
| Final | 12/19/2016 | 12/20/2016 | 12/20/2016 10:31:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dean Gernaat Final ok
|
ELE16-04070
| Rough-In Permanent Service | 12/20/2016 | 12/20/2016 | 12/20/2016 9:26:44 AM | A | FAIL |
|
|
ROUGH IN HOUSE AND GARAGE. PERMANENT SERVICE Phone #: ###-#### Inspection requested via web by mike brown * No access to loft above garage. 300.15- All outdoor receptacle outlets shall have boxes. Light under stair wire not in box. 300.4- SER above panel needs nail plates. 230.79- 50 amp installed and labelled for garage, shall be 60 amp minimum
|
ELE16-04043
| Rough-In Permanent Service | 12/16/2016 | 12/20/2016 | 12/20/2016 8:51:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Zane Robertson Receptacle needed master bed behind door, pocket door will create 5' wall space. Will check on final. Rough in ok cover p/s u/g n ok
|