MEC18-05232
| Final | 12/19/2018 | 12/20/2018 | 12/20/2018 3:28:27 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Profitt - 1" clearances on b vent roof membrane is touching flue from below roof line
|
MEC18-05616
| Final | 12/19/2018 | 12/20/2018 | 12/20/2018 3:24:45 PM | P | FAIL |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 3:00 PM . Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette - 5lb flue test fail
|
MEC18-06045
| Final | 12/20/2018 | 12/20/2018 | 12/20/2018 2:24:02 PM | P | PASS |
|
|
Please call Melton Kutsurelis (###-####) 30 minutes prior to showing up, Thank you Phone #: ###-#### Inspection requested via web by Tyler Collado - electric furnace ac coil ok
|
MEC18-06041
| Final | 12/19/2018 | 12/20/2018 | 12/20/2018 1:58:44 PM | P | PASS |
|
|
Early PM pease call Joseph prior to arrival ###-#### Inspection requested via web by Arielle Hendricks - furnace only co ok
|
MEC18-06041
| Pressure Test | 12/20/2018 | 12/20/2018 | 12/20/2018 1:58:27 PM | P | PASS |
|
|
Pressure Test Flue - Joseph ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 5lb flue pressure test ok
|
MEC18-05970
| Final | 12/19/2018 | 12/20/2018 | 12/20/2018 1:41:35 PM | P | PASS |
|
|
Please call Chris on way to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout - furnace ac coil co ok
|
MEC18-05988
| Rough-in | 12/19/2018 | 12/20/2018 | 12/20/2018 1:11:28 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero - need to see framing around fireplace flue
|
MEC18-06004
| Final | 12/19/2018 | 12/20/2018 | 12/20/2018 10:45:58 AM | A | FAIL |
|
|
if questions call Jared @ ###-#### or Jerry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann - pressure gauge was under 20lb - need to see two shut off valves with a tee between the two valves on a live gas line or disconnect new gas line from live gas line for pressure test
|
MEC18-06004
| Pressure Test | 12/20/2018 | 12/20/2018 | 12/20/2018 10:42:46 AM | A | FAIL |
|
|
if questions call Jared @ ###-#### or Jerry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann - 20lb gas pressure test fail gauge was under 20 lb - need to see two shut off valves with an open tee between the two valves when connected to live gas line
|
MEC18-05521
| Rough-in | 12/19/2018 | 12/20/2018 | 12/20/2018 10:18:06 AM | A | NR |
|
|
DOUG ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|
MEC18-04154
| Conference | 12/19/2018 | 12/20/2018 | 12/20/2018 9:52:53 AM | A | DONE |
|
|
LATE A.M. CONFERENCE PLEASE CALL DUSTIN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt -met with Dustin from western hvac - dryer vent is free of screws and roof cap is ok - condensate for furnace is ok and support of condensate is ok - gas line sediment trap ok and supports ok - water heater b vent 1" clearances ok - exhaust fans ducting ok - still need to see a Man J performed and onsite with balance and duct blast report -supplys needs balance dampers - attic access needs pathway finished and platform needs extended
|
MEC18-05881
| Rough-in | 12/19/2018 | 12/20/2018 | 12/20/2018 9:11:02 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - line set has torn insulation in attic and wall - crawl not finished - bathroom exhaust ducts need sealed at connection
|
MEC18-05881
| Pressure Test | 12/19/2018 | 12/20/2018 | 12/20/2018 9:09:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 20lb gas pressure test ok - 5lb flue pressure test ok
|
MEC18-04955
| Final | 12/19/2018 | 12/20/2018 | 12/20/2018 8:40:46 AM | A | FAIL |
|
|
FINAL REQUEST PLEASE, OPEN JOB SITE WITH OTHER CONTRACTORS WORKING. I LEFT MY OFFICE NUMBER IF THERE IS ISSUE, MY NAME IS STEVE DALE, THANKS SO MUCH Phone #: ###-#### Inspection requested via web by Rick Montgomery - line sets at outdoor unit need uv protection
|
MEC18-05811
| Final | 12/17/2018 | 12/20/2018 | 12/20/2018 8:07:12 AM | A | CANC |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 10. Contact for Right Now is Mary ###-####
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|
MEC17-01455
| Mec-Aging Inspection | 12/20/2018 | 12/20/2018 | 12/20/2018 8:07:06 AM | | FAIL |
|
|
-contractor has not made contact with the city and no inspection has been made - scheduled inspection
|
MEC18-05810
| Final | 12/17/2018 | 12/20/2018 | 12/20/2018 8:07:05 AM | A | CANC |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 10:00 . Contact for Right Now is Mary ###-####
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|
MEC17-04523
| Mec-Aging Inspection | 12/20/2018 | 12/20/2018 | 12/20/2018 8:05:42 AM | | FAIL |
|
|
- need to call fireplace in for a final
|
MEC18-05508
| Final | 12/14/2018 | 12/20/2018 | 12/14/2018 3:46:34 PM | P | CANC |
|
|
Please inspect after 3:45. Kenneth Camacho get off work at 3:30 and will be home at 3:45. ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
|