MEC19-05726
| Conference | 12/19/2019 | 12/20/2019 | 12/20/2019 4:26:36 PM | P | DONE |
|
|
Hello Jack. I spoke to you about adding a gas line from the supply line in the garage, under the floor of the house, and back up into the kitchen. If there is any way you can make me your last appointment of the day, that would be GREAT! Thank you! And thanks again for ALL of your help over the phone. Phone #: ###-#### Inspection requested via web by Dean Dryer - checked gas pipe sizing for homeowner on existing lines to make sure a range could be added. - talked over setting up gas line pressure test and supporting gas line.
|
MEC19-05719
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 3:30:22 PM | P | PASS |
|
|
Please call Louie on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks 2-5lb flue pressure tests ok 2- furnaces only co ok
|
MEC19-05734
| Rough-in | 12/20/2019 | 12/20/2019 | 12/20/2019 3:06:09 PM | P | FAIL |
|
|
CALL CHRIS PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Jamee Shoecraft - unvented room heater should be listed with ANSI Z 21.11.2 and tag could not be found on equipment -need to see access to gas valve behind unit - CSST behind unit needs supported
|
MEC19-05695
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 3:04:34 PM | P | PASS |
|
|
Call on way: Aleks ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace ac coil co ok
|
MEC19-05715
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 2:15:28 PM | P | PASS |
|
|
please call Tanner on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace ac coil co ok
|
MEC19-04662
| Rough-in | 12/19/2019 | 12/20/2019 | 12/20/2019 2:15:01 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - Talked with builder onsite about having a conference inspection with the building inspector about the floor joist that was cut. - will not pass R/I until joist is checked by building inspector. - re inspection fee applied
|
MEC19-05155
| Final | 12/13/2019 | 12/20/2019 | 12/20/2019 1:37:24 PM | P | PASS |
|
|
Please call Jack in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout - final ok
|
MEC19-05712
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 1:27:24 PM | P | FAIL |
|
|
Diann Sivels ###-#### Inspection requested via web by Margie Rowe - line set penetration needs sealed - gas line at furnace needs supported - single wall flue needs 6" clearances to combustibles or b vent installed
|
MEC19-04660
| Rough-in | 12/19/2019 | 12/20/2019 | 12/20/2019 12:58:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - R/I ok
|
MEC19-04661
| Rough-in | 12/19/2019 | 12/20/2019 | 12/20/2019 12:58:19 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart -R/I ok
|
MEC19-01016
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 11:49:00 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth - final ok
|
MEC19-05620
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 11:15:06 AM | A | FAIL |
|
|
Elton ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - single wall flue needs 6" clearances or b vent installed
|
MEC19-05713
| Pressure Test | 12/19/2019 | 12/20/2019 | 12/20/2019 11:11:09 AM | A | PART |
|
|
Please call Jake 30 min prior to arrival so we can meet you onsite ###-#### Phone #: ###-#### Inspection requested via web by Nicholas Paige - 60lb gas pressure test ok - will need to see permit issued for equipment before final. So equipment can be inspected to manufactures specs/listing
|
MEC19-04639
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 10:04:45 AM | A | PASS |
|
|
Need to spend pictures of corrected work to Jack Inspection requested via web by Dan McFate - final ok
|
MEC19-01639
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 10:04:24 AM | A | PASS |
|
|
Need to send pictures of completed corrections to Jack Phone #: ###-#### Inspection requested via web by Dan McFate - final ok
|
MEC19-05684
| Final | 12/19/2019 | 12/20/2019 | 12/20/2019 9:51:26 AM | A | PASS |
|
|
Please call Rick @ ###-#### when you are headed to the residence Phone #: ###-#### Inspection requested via web by Sarah Small - furnace only co ok
|
MEC19-05047
| Final | 12/17/2019 | 12/20/2019 | 12/20/2019 9:28:10 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by James Cox - no access to home left notice on front door
|
MEC19-05441
| Final | 12/17/2019 | 12/20/2019 | 12/20/2019 9:13:50 AM | A | PASS |
|
|
Homeowner Tim Johnstone ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace only co ok
|
MEC19-05607
| Final | 12/20/2019 | 12/20/2019 | 12/20/2019 8:57:34 AM | A | PASS |
|
|
CALL HOMEOWNER THIS IS UNIT #16 Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace ac coil co ok
|
MEC18-05424
| Mec-Aging Inspection | 12/20/2019 | 12/20/2019 | 12/20/2019 8:20:11 AM | | PASS |
|
|
wip
|