Inspections for the day of: Friday, December 20, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05726 Conference12/19/201912/20/201912/20/2019 4:26:36 PMPDONE
Hello Jack. I spoke to you about adding a gas line from the supply line in the garage, under the floor of the house, and back up into the kitchen. If there is any way you can make me your last appointment of the day, that would be GREAT! Thank you! And thanks again for ALL of your help over the phone. Phone #: ###-#### Inspection requested via web by Dean Dryer
- checked gas pipe sizing for homeowner on existing lines to make sure a range could be added.
- talked over setting up gas line pressure test and supporting gas line.
MEC19-05719 Final12/19/201912/20/201912/20/2019 3:30:22 PMPPASS
Please call Louie on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
2-5lb flue pressure tests ok
2- furnaces only co ok
MEC19-05734 Rough-in12/20/201912/20/201912/20/2019 3:06:09 PMPFAIL
CALL CHRIS PRIOR TO ARRIVAL Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
- unvented room heater should be listed with ANSI Z 21.11.2 and tag could not be found on equipment
-need to see access to gas valve behind unit
- CSST behind unit needs supported
MEC19-05695 Final12/19/201912/20/201912/20/2019 3:04:34 PMPPASS
Call on way: Aleks ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- furnace ac coil co ok
MEC19-05715 Final12/19/201912/20/201912/20/2019 2:15:28 PMPPASS
please call Tanner on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- furnace ac coil co ok
MEC19-04662 Rough-in12/19/201912/20/201912/20/2019 2:15:01 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart
- Talked with builder onsite about having a conference inspection with the building inspector about the floor joist that was cut.
- will not pass R/I until joist is checked by building inspector.
- re inspection fee applied
MEC19-05155 Final12/13/201912/20/201912/20/2019 1:37:24 PMPPASS
Please call Jack in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- final ok
MEC19-05712 Final12/19/201912/20/201912/20/2019 1:27:24 PMPFAIL
Diann Sivels ###-#### Inspection requested via web by Margie Rowe
- line set penetration needs sealed
- gas line at furnace needs supported
- single wall flue needs 6" clearances to combustibles or b vent installed
MEC19-04660 Rough-in12/19/201912/20/201912/20/2019 12:58:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
- R/I ok
MEC19-04661 Rough-in12/19/201912/20/201912/20/2019 12:58:19 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
-R/I ok
MEC19-01016 Final12/19/201912/20/201912/20/2019 11:49:00 AMAPASS
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth
- final ok
MEC19-05620 Final12/19/201912/20/201912/20/2019 11:15:06 AMAFAIL
Elton ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- single wall flue needs 6" clearances or b vent installed
MEC19-05713 Pressure Test12/19/201912/20/201912/20/2019 11:11:09 AMAPART
Please call Jake 30 min prior to arrival so we can meet you onsite ###-#### Phone #: ###-#### Inspection requested via web by Nicholas Paige
- 60lb gas pressure test ok
- will need to see permit issued for equipment before final. So equipment can be inspected to manufactures specs/listing
MEC19-04639 Final12/19/201912/20/201912/20/2019 10:04:45 AMAPASS
Need to spend pictures of corrected work to Jack Inspection requested via web by Dan McFate
- final ok
MEC19-01639 Final12/19/201912/20/201912/20/2019 10:04:24 AMAPASS
Need to send pictures of completed corrections to Jack Phone #: ###-#### Inspection requested via web by Dan McFate
- final ok
MEC19-05684 Final12/19/201912/20/201912/20/2019 9:51:26 AMAPASS
Please call Rick @ ###-#### when you are headed to the residence Phone #: ###-#### Inspection requested via web by Sarah Small
- furnace only co ok
MEC19-05047 Final12/17/201912/20/201912/20/2019 9:28:10 AMANH
Phone #: ###-#### Inspection requested via web by James Cox
- no access to home left notice on front door
MEC19-05441 Final12/17/201912/20/201912/20/2019 9:13:50 AMAPASS
Homeowner Tim Johnstone ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC19-05607 Final12/20/201912/20/201912/20/2019 8:57:34 AMAPASS
CALL HOMEOWNER THIS IS UNIT #16 Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace ac coil co ok
MEC18-05424 Mec-Aging Inspection12/20/201912/20/201912/20/2019 8:20:11 AM PASS
wip