ELE07-03652
| Final | 12/21/2007 | 12/21/2007 | 12/21/2007 4:04:14 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 12/21/2007 at 10:39:09 AM. Contact: ###-####. ok to final, signed structural card
|
ELE07-03653
| Final | 12/21/2007 | 12/21/2007 | 12/21/2007 3:32:10 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 12/21/2007 at 10:38:16 AM. Contact: ###-####. ok to final, signed structural card
|
ELE07-00396
| Final | 12/21/2007 | 12/21/2007 | 12/21/2007 2:58:18 PM | P | PASS |
|
|
jim Phone #: ###-#### met electricians, corrections made, ok to final
|
ELE07-03565
| Final | 12/21/2007 | 12/21/2007 | 12/21/2007 2:17:52 PM | P | PASS |
|
|
hz Phone #: ###-#### ok to final
|
ELE07-04194
| Temporary Service | 12/21/2007 | 12/21/2007 | 12/21/2007 1:32:22 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 12/21/2007 at 9:33:01 AM. Contact: ###-####. called contr, t/s o/h n ok
|
ELE07-01624
| Electrical Rough-In | 12/21/2007 | 12/21/2007 | 12/21/2007 12:55:04 PM | P | PASS |
|
|
steve Phone #: ###-#### ok to cover west stairwell
|
ELE07-03241
| Final | 12/20/2007 | 12/21/2007 | 12/21/2007 11:13:04 AM | A | PASS |
|
|
We have made the nessary corrections Phone #: ###-#### Internet Inspection Request from: Scott Abbott corrections made, signed occupancy card, ok to final
|
ELE07-03867
| Conference | 12/20/2007 | 12/21/2007 | 12/21/2007 10:27:06 AM | A | DONE |
|
|
Alejandro ###-#### please call when on way homeowner not sure there will be any wiring required, told that if any wiring done or exposed we need to do ri inspection before cover
|
ELE07-04188
| Rough-In Permanent Service | 12/20/2007 | 12/21/2007 | 12/21/2007 10:07:40 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 12/20/2007 at 3:22:40 PM. Contact: ###-####. called contractor, left correction notice, nec 334.30(A) rmc shall be securely fastened within 3' of service head for above roof termination of mast, 352.30(A) rnc shall be secured within 3' of grade, 352.30(B) rnc shall be strapped every 5', 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members
|
ELE07-04188
| Electrical Rough-In | 12/21/2007 | 12/21/2007 | 12/21/2007 10:01:24 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 12/20/2007 at 3:22:40 PM. Contact: ###-####. called contr about nail plates, ric ok
|
ELE07-04185
| Permanent Service | 12/20/2007 | 12/21/2007 | 12/21/2007 9:30:04 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Steve Craig p/s o/h rec ok
|
ELE07-04181
| Electrical Rough-In | 12/20/2007 | 12/21/2007 | 12/21/2007 9:12:33 AM | A | PASS |
|
|
richard - uffer Phone #: ###-#### ok to backfill concrete encased electrode
|
ELE07-03785
| Electrical Rough-In | 12/20/2007 | 12/21/2007 | 12/21/2007 8:44:34 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Kerri Hamiltonnnnok to cover ceiling anop
|
ELE07-04187
| Final | 12/20/2007 | 12/21/2007 | 12/21/2007 8:31:36 AM | A | PASS |
|
|
steve Phone #: ###-#### called contractor, ok to final
|
ELE07-04147
| Final | 12/20/2007 | 12/21/2007 | 12/20/2007 12:38:22 PM | A | CANC |
|
|
electrician is Nick Felsted Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer Inspection cancelled from web by: gary batten
|