Inspections for the day of: Tuesday, December 21, 2010.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorClint A Smith
TitleEROSION CONTROL INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC09-00776 General Inspection12/21/201012/21/201012/22/2010 1:40:22 PM DONE
WOrk has been completed. Contacted building inspector and informed him of the status of the BLD permit.
ESC09-00775 General Inspection12/21/201012/21/201012/21/2010 3:55:05 PM DONE
Permit finalled.
ESC09-00775 DOC - Permit Finaled12/21/201012/21/201012/21/2010 3:54:56 PMPPASS
ESC10-00569 Random Inspection12/21/201012/21/201012/21/2010 3:54:43 PMPFAIL
Verbal to RP:
Clean up all tracking off of lot from the delivery of materials. Will re-inspect on 12/22/2010PM.
ESC09-00778 General Inspection12/21/201012/21/201012/21/2010 2:53:10 PM DONE
ESC09-00778 DOC - Permit Finaled12/21/201012/21/201012/21/2010 2:52:56 PMPPASS
ESC09-00778 DOC - Permit Finaled12/21/201012/21/201012/21/2010 2:51:36 PMPPASS
ESC09-00772 General Inspection12/21/201012/21/201012/21/2010 2:51:20 PM DONE
Permit finalled.
ESC09-00765 General Inspection12/21/201012/21/201012/21/2010 2:51:20 PM DONE
Permit finalled.
ESC09-00772 DOC - Permit Finaled12/21/201012/21/201012/21/2010 2:51:19 PMPPASS
ESC09-00765 DOC - Permit Finaled12/21/201012/21/201012/21/2010 2:51:19 PMPPASS
ESC09-00765 DOC - Permit Finaled12/21/201012/21/201012/21/2010 2:51:18 PMPPASS
ESC09-00765 DOC - Permit Finaled12/21/201012/21/201012/21/2010 2:51:10 PMPPASS
ESC09-00744 General Inspection12/21/201012/21/201012/21/2010 1:14:32 PM PASS
Permit was finaled.
ESC09-00744 DOC - Permit Finaled12/21/201012/21/201012/21/2010 1:14:05 PMPPASS
ESC10-00764 Site Preparation12/21/201012/21/201012/21/2010 11:33:06 AMAFAIL
*CORRECTION NOTICE*
Could not reach contractor
1. Provide a valid RP who has day to day control of the erosion and sediment issues through out the duration of the project.
**Failure to comply with the posted notice will result in a Stop Work Order.

Daisy Glenn who is listed as the RP has no knowledge of the project. Will re-inspect on 12/22/2010 PM
ESC10-00888 Site Preparation12/21/201012/21/201012/21/2010 10:04:58 AMPFAIL
Vverbal to RP:
Provide sediment barrier along alley way and property line where stockpile is located.
Post ESC sign where visable from the street. Will re-inspect on 12/22/2010am.
ESC09-00790 General Inspection12/21/201012/21/201012/21/2010 7:53:43 AM DONE
Permit os finalled.
ESC09-00790 DOC - Permit Finaled12/21/201012/21/201012/21/2010 7:53:34 AMPPASS