Inspections for the day of: Wednesday, December 21, 2011.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02593 Final12/21/201112/21/201112/21/2011 3:13:40 PMPPASS
THANKS Phone #: ###-#### >> Inspection requested via web by Bob Glenn ok final
ELE11-02419 Final12/21/201112/21/201112/21/2011 3:06:45 PMPPASS
THANKS Phone #: ###-#### >> Inspection requested via web by Bob Glenn ok final
ELE11-02865 Final12/21/201112/21/201112/21/2011 2:47:29 PMPCANC

we are replacing the 98 fluorescent fixtures in the main plant area with high-bay 6 tube t8 fixtures prewired with cords and lamps Phone #: ###-#### >> Inspection requested via web by patrick marks see ri fail
ELE11-02865 Electrical Rough-In12/21/201112/21/201112/21/2011 2:46:17 PMPFAIL

we are replacing the 98 fluorescent fixtures in the main plant area with high-bay 6 tube t8 fixtures prewired with cords and lamps Phone #: ###-#### >> Inspection requested via web by patrick marks called, told correction notice NEC 410.62(C)(1)(1) the luminaire shall be directly below outlet
ELE11-02749 Final12/21/201112/21/201112/21/2011 2:10:06 PMPPASS
Corrections made & ready for re-inspection. That riser was installed by others, but I strapped it.
Thanks, Dan. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell corrections made, ok final
ELE11-02772 Electrical Rough-In12/21/201112/21/201112/21/2011 1:47:55 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by John VanZandt corrections not all done
ELE11-02720 Final12/21/201112/21/201112/21/2011 12:26:41 PMPNR
Electrician is Nate. Phone #: ###-#### >> Inspection requested via web by joel smith called in wrong day
ELE11-02855 Electrical Rough-In12/20/201112/21/201112/21/2011 11:54:02 AMAPASS
Please inspect ufer ground. Phone #: ###-#### >> Inspection requested via web by Kevin Perez ok pour concrete encased electrode
ELE11-02852 Rough-In Permanent Service12/20/201112/21/201112/21/2011 10:32:44 AMAFAIL
Thank you Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe called, told to add outlets in office area in kitchen per NEC 210.52
ELE11-02853 Rough-In Permanent Service12/20/201112/21/201112/21/2011 10:17:52 AMAPASS
Thank you Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe called , told to ground metal boxes on island, ri ok, p/s u/g n ok
ELE11-02254 Permanent Service12/19/201112/21/201112/21/2011 9:16:02 AMAPASS
casey Phone #: ###-#### - please call 1/2 hr prior so he can meet you there check strapping, bushings, nail plates at final, p/s u/g n (rec) ok
ELE11-02749 Final12/16/201112/21/201112/21/2011 8:44:09 AMAFAIL
Key is above door or exterior light, please replace it when done.
Thanks,
Dan. Phone #: ###-#### >> Inspection requested via web by Dan Mitchell called, shall strap riser, shall provide gfci that functions
ELE11-02593 Final12/20/201112/21/201112/21/2011 8:25:50 AMAPASS
GARAGE CODE 9834 Phone #: ###-#### >> Inspection requested via web by Bob Glenn ok final