Inspections for the day of: Wednesday, December 21, 2016.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Sly
TitleBLD-COM/RES INSPECTOR
Phone #794-9465
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-03755 BLD-Final12/21/201612/21/201612/22/2016 10:08:21 AMPPEND
Walter Phone #: ###-####
Re-scheduled.
BLD16-04140 BLD-Footing12/21/201612/21/201612/21/2016 5:08:36 PMPNR
Serigo Phone #: ###-####
No call from concrete contractor that they had no intension of pouring footing. I arrived to find that the excavation for footings was done on Monday. The average daily temp has been 23 degrees for last 2 days. The ground is frozen, and workers are covering it with plastic covering. There are 2 propane heaters staged for future use. It took me 1 hr to find this site. I called concrete contractor (sergio) and any phone # I could find for Brigjhton Homes. No return calls.
BLD16-04553 BLD-Final12/21/201612/21/201612/21/2016 4:48:23 PMPPASS
Walter Phone #: ###-####
BLD16-04553 DOC - Permit Finaled12/21/201612/21/201612/21/2016 4:48:09 PMPPASS
BLD16-00611 BLD-Wall Bracing12/21/201612/21/201612/21/2016 3:18:36 PMPPASS
Shear // Loun Phone #: ###-####
BLD16-03167 BLD-Energy code compliance12/21/201612/21/201612/21/2016 2:38:41 PMPPASS
Kyle Phone #: ###-####
MIS16-00394 BLD-Conference12/21/201612/21/201612/21/2016 2:07:04 PMPPEND
Front and back door or being replace with bigger doors so the walls are being cut to widen the spaces.
Doors are not being installed at this time .....shipped wrong sizes. Talked to Kacey from View Point Windows and the Homeowner. Verbal.....permit will be required if framing is changed to accept a larger window.
BLD16-02944 BLD-Framing/Rough-in12/21/201612/21/201612/21/2016 2:02:32 PMPPASS
Erby Phone #: ###-####
BLD16-02945 BLD-Framing/Rough-in12/21/201612/21/201612/21/2016 2:02:15 PMPPASS
Erby Phone #: ###-####
BLD16-03261 BLD-Framing/Rough-in12/20/201612/21/201612/21/2016 12:07:45 PMAPART
Kris-back side of home-go thru gate on garage side of house Phone #: ###-####
OK except want contr yo add to top chord trusses
BLD16-03662 BLD-Ceiling Grid Inspection12/20/201612/21/201612/21/2016 11:25:30 AMAPASS
Randy Phone #: ###-####
BLD16-03741 BLD-Framing/Rough-in12/20/201612/21/201612/21/2016 11:12:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Brad Zollinger
BLD16-04007 BLD-Footing12/20/201612/21/201612/21/2016 11:11:47 AMAFAIL
Please call Jared at ###-#### 1/2 hr before inspection.
Requested inspection time after 10 am. Phone #: ###-#### Inspection requested via web by Jared Waggoner
Requires special inspection.....3,000 to 4,000 psi concrete. Plans were not stamped approved. cannot pour without forms and subgrade at min. 35 degrees. Cannot pour without external heat source. "cold Weather conditions" three consecutive days will be less than 40 degrees. last night 18 degrees.....next three days 21-10 24-18 26-20. Need to maintain min. 50 degrees for min. 3 days. above per ACI 306 standard for cold weather concrete.