ELE12-01902
| ELE-Aging Inspection | 12/21/2017 | 12/21/2017 | 12/27/2017 7:57:19 AM | | FAIL |
|
|
still waiting on contractor to get access and schedule...has been contacted multiple times
|
ELE12-01900
| ELE-Aging Inspection | 12/21/2017 | 12/21/2017 | 12/27/2017 7:56:45 AM | | FAIL |
|
|
still waiting on contractor to get access and schedule...has been contacted multiple times
|
ELE13-03397
| ELE-Aging Inspection | 12/21/2017 | 12/21/2017 | 12/22/2017 2:45:40 PM | | PASS |
|
|
final scheduled
|
ELE17-04291
| Conference | 12/21/2017 | 12/21/2017 | 12/21/2017 3:22:26 PM | P | PASS |
|
|
Randy Phone #: ###-####-please call to meet...discussed wiring requirements for second half of house tied to a MH already wired, service requirements and options, temp power for construction...homeowners pamphlet given...homeowner knowledgeable
|
ELE17-03918
| Electrical Rough-In | 12/20/2017 | 12/21/2017 | 12/21/2017 1:38:53 PM | P | PASS |
|
|
Rough in please. Have a bless Christmas!!! Phone #: ###-#### Inspection requested via web by Kyle Lott...exterior walls drive thru area, bathrooms, back employee area, other areas discussed with contractor
|
ELE17-03186
| Final | 12/21/2017 | 12/21/2017 | 12/21/2017 1:07:56 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ben Archibald.... 1) master stool area needs completed...110.7 2) circuit for disposal in dining sink shall be finished/added/completed for final...110.3 3) shower can trim needs verified rated for installation in shower...110.3
|
ELE17-03501
| Final | 12/21/2017 | 12/21/2017 | 12/21/2017 12:18:01 PM | P | PASS |
|
|
Justin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...corrections made...ok to final
|
MIS17-00431
| ELE-Conference | 12/21/2017 | 12/21/2017 | 12/21/2017 11:40:04 AM | P | PASS |
|
|
electrical work has been done without a permit...stop work order and correction notice posted...future inspection schedule for 1/4/18 unless permits are pulled and inspections scheduled
|
ELE17-04276
| Final | 12/21/2017 | 12/21/2017 | 12/21/2017 11:14:17 AM | P | PASS |
|
|
Ground rods have been installed. Inspection requested via web by Clint Tate...ok to final...no distribution out of panel...permit to energize service only
|
ELE17-04276
| Permanent Service | 12/21/2017 | 12/21/2017 | 12/21/2017 11:13:17 AM | P | PASS |
|
|
Ground rods have been installed. Inspection requested via web by Clint Tate...p/s o/h new ok
|
ELE17-04211
| Final | 12/15/2017 | 12/21/2017 | 12/21/2017 10:45:36 AM | A | PASS |
|
|
Call on way-###-####. Inspection requested via web by Same Electric...final for this permit...ceiling fan was added in basement and exhaust fan added in upstairs bath ok...other work was done by other electrician under permit ELE17-02413 and has not been finished and scheduled for final...this final will not final out that work
|
ELE17-04089
| Rough-In Permanent Service | 12/20/2017 | 12/21/2017 | 12/21/2017 9:57:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall...rough ok to cover...p/s u/g new 5 meters
|
ELE17-03475
| Final | 12/20/2017 | 12/21/2017 | 12/21/2017 9:08:12 AM | A | PASS |
|
|
garage code 2468 Phone #: ###-#### Inspection requested via web by Darryn Coburn...ok to final
|