Inspections for the day of: Thursday, December 22, 2005.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-00535 Conference12/21/200512/22/200512/22/2005 2:05:30 PMPCANC
anthony; Phone #: ###-#### Internet Inspection Request from: Barbara Moore this should be a final not conference, no more conferences allowed see added final
ELE05-04473 Electrical Rough-In12/22/200512/22/200512/22/2005 1:10:05 PMPPART
pipes in concrete slab///rick; Phone #: ###-#### Internet Inspection Request from: Barbara ok
ELE05-04549 Rough-In Permanent Service12/21/200512/22/200512/22/2005 10:51:23 AMAFAIL
nicole; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
cor. called left message, needs 11/4" and nail plates, 110.3,314.17,110.12 replace all outside boxes with broken out factory clamps, replace all boxes with extra KOs broken out, 334.24 all cables shall have a radius of not less than 5 times the diameter
ELE05-03998 Final12/22/200512/22/200512/22/2005 10:25:55 AMAPASS
U.L. certification is done and ready for Final Insp. now. Thanks !!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE05-04528 Final12/22/200512/22/200512/22/2005 10:25:36 AMAPASS
We Wired some new light fixtures indoors with a new switch by the back door, and we wired a receptacle for his air pump. Jody (man) or his shop foreman will give you the Tour. Thanks !!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE05-04591 Permanent Service12/22/200512/22/200512/22/2005 9:48:30 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer p/s o/h new ok
ELE05-04151 Electrical Rough-In12/21/200512/22/200512/22/2005 9:04:04 AMANR
###-#### Note: underground pipe in concrete slab - in the kitchen area
ELE05-04579 Rough-In Permanent Service12/21/200512/22/200512/22/2005 8:47:54 AMAPASS
alan ###-#### r/i ok p/s u/g new ok
ELE05-01814 Rough-In Permanent Service12/21/200512/22/200512/22/2005 8:47:25 AMACANC
Scheduled by a contractor via Hello! on 12/21/2005 at 3:10:14 PM. Contact: ###-####. contractor canceled
ELE05-04551 Temporary Service12/22/200512/22/200512/22/2005 8:17:22 AMAPASS
Jack I vacumed out this pole last night.; Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman t/s u/g new ok
ELE05-00535 Final12/22/200512/22/200512/22/2005 12:00:00 AMPFAIL
anthony; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
cor. posted needs afci for bed rm circuits, switches and recepts shall be secure in boxes and flush with plates, covers for all boxes, install panel cover and label, correct wiring in NW bed rm cow