Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-03427 Final12/22/201512/22/201512/22/2015 2:34:24 PMPCANC
Job Foreman: Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher Rescheduled to tomorrow AM due to holiday traffic at mall
ELE15-04057 Rough-In Permanent Service12/21/201512/22/201512/22/2015 2:06:17 PMPPASS
Phone #: ###-#### Inspection requested via web by Rowdy Monroe
Note on temp pole- 590.6- all 120 volt temp receptacles shall have GFCI protection. Black GFI did not trip when tested.
House rough in ok cover p/s o/h n ok
ELE15-01468 Electrical Rough-In12/22/201512/22/201512/22/2015 1:30:35 PMPFAIL
Mason Phone #: ###-#### turned into another conference. Discussed 2 20 amp circuits serving kitchen counter top receptacles, dining, and pantry receptacles and shall have no other outlets. Securing NM cable with in 12 " of boxes. NM cables shall be contained in stud bays. Discussed nail plates.
ELE15-04060 Rough-In Permanent Service12/22/201512/22/201512/22/2015 12:48:44 PMPFAIL
rough-in Phone #: ###-#### Inspection requested via web by cal crosby
250.28- Main bonding jumper screw shall be installed.
300.4- NM cable and bell wire shall be protected from physical damage where ran through bored holes that do not maintain 1 1/4" from framing surface. garage outlet, garage door sensor wires.
408.7- Unused breaker spaces shall be closed.
ELE15-04040 Rough-In Permanent Service12/21/201512/22/201512/22/2015 11:57:22 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson Rough in ok cover p/s u/g n ok
ELE15-03400 Final12/22/201512/22/201512/22/2015 11:20:45 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
Final ok
ELE15-03723 Rough-In Permanent Service12/22/201512/22/201512/22/2015 10:46:14 AMAPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov
Rough in ok cover p/s u/g n ok
ELE15-03654 Final12/22/201512/22/201512/22/2015 10:04:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
ELE15-03571 Final12/22/201512/22/201512/22/2015 9:42:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
ELE15-02908 Electrical Rough-In12/21/201512/22/201512/22/2015 9:31:16 AMAPASS
We are requesting a hard rock ceiling inspection for the bathroom for tomorrow 12/22/15 in the AM. Our contact is Rod @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Bathroom hardlid rough in ok cover