ELE16-03996
| Final | 12/22/2016 | 12/22/2016 | 12/22/2016 2:15:00 PM | P | PASS |
|
|
Kyle Phone #: ###-#### Final ok
|
ELE16-01946
| Electrical Rough-In | 12/22/2016 | 12/22/2016 | 12/22/2016 1:42:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 1st floor and mezz walls as noted on contractor print rough in ok cover
|
ELE16-03034
| Final | 12/22/2016 | 12/22/2016 | 12/22/2016 1:13:33 PM | P | PASS |
|
|
Ken Phone #: ###-#### Listing and disconnecting means confirmed. Final ok
|
ELE16-03794
| Electrical Rough-In | 12/22/2016 | 12/22/2016 | 12/22/2016 1:04:11 PM | P | FAIL |
|
|
Inspect can light frame rough-in and installed strip lighting in elevator lobby and halls. 9th floor Phone #: ###-#### Inspection requested via web by steve ragan BCC 4-05-32- code violations not to be retained. 300.15- All splice point shall be contained in a box. 314.25- All boxes shall have covers installed. 358.30- Support for existing conduits has been removed at some point. Each Emt conduit shall be supported with in 3' of a box and shall have supports not to exceed 10' between.
|
ELE16-03822
| Final | 12/22/2016 | 12/22/2016 | 12/22/2016 12:27:50 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Steve Craig Final ok
|
ELE16-03865
| Permanent Service | 12/21/2016 | 12/22/2016 | 12/22/2016 10:50:40 AM | A | PASS |
|
|
Please call James Buckley first ###-####. It has a gate and he will give you instructions. This is to energize the service.
Phone #: ###-#### Inspection requested via web by A.M.E. Office Added new main disconnect on exterior or building. p/s u/g rec ok
|
ELE14-02219
| Final | 12/21/2016 | 12/22/2016 | 12/22/2016 10:32:07 AM | A | PASS |
|
|
Scott Phone #: ###-#### Final ok
|
ELE15-03553
| Final | 12/21/2016 | 12/22/2016 | 12/22/2016 10:31:34 AM | A | PASS |
|
|
Scott Phone #: ###-#### Checked whole house. All devices upgraded. Final ok
|
ELE16-03331
| Final | 12/21/2016 | 12/22/2016 | 12/22/2016 9:36:50 AM | A | PASS |
|
|
Re-routed conduit around new door opening, Installed circuits for 4 new pieces of equipment, Added several outlets This place is fairly big and cluttered, It might be best if you call me before you head that way so I can meet you to go through what we did Phone #: ###-#### Inspection requested via web by Troy Cobb Final ok
|
ELE16-03331
| Electrical Rough-In | 12/22/2016 | 12/22/2016 | 12/22/2016 9:36:02 AM | P | PASS |
|
|
Re-routed conduit around new door opening, Installed circuits for 4 new pieces of equipment, Added several outlets This place is fairly big and cluttered, It might be best if you call me before you head that way so I can meet you to go through what we did Phone #: ###-#### Inspection requested via web by Troy Cobb All wiring fished or surface mounted. Rough in ok
|
ELE16-03822
| Final | 12/22/2016 | 12/22/2016 | 12/22/2016 8:57:26 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Steve Craig Still working on lighting issues, receptacle on south wall in-op, GFCI in-op east by baths. Will recall when complete
|