Inspections for the day of: Thursday, December 22, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02903 ELE-Aging Inspection12/22/201612/22/201612/23/2016 12:12:33 PM PASS
spoke with richard...will schedule in next couple weeks
ELE16-04067 Final12/22/201612/22/201612/22/2016 2:24:32 PMPPASS
Call half hour before to meet // Mike Phone #: ###-####....

ok to final
ELE16-04094 Electrical Rough-In12/22/201612/22/201612/22/2016 1:35:28 PMPPASS
We are requesting a partial wall rough-in inspection for this afternoon. Our onsite contact is Bud @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate...

wall cover ok - warehouse wall and room divider walls
ELE16-02719 Final12/22/201612/22/201612/22/2016 12:12:26 PMPFAIL
Phone #: ###-#### Inspection requested via web by Therrin Robertson....

1) front w/p outlet no power
2) front w/p hot/neutral reversed
3) powder bath outlet shows open ground
4) quad outlet in hallway has outlet with no power
5) missing switch cover plate upstairs bed closet
6) sub panel needs labelled correctly-mst bath
7) pool panel...breakers installed not labelled
used for blanks? future circuits?
ELE16-04071 Rough-In Permanent Service12/21/201612/22/201612/22/2016 10:54:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt....

rough ok to cover
p/s u/g n ok
ELE16-03745 Final12/21/201612/22/201612/22/2016 10:14:08 AMANR
Phone #: ###-#### Inspection requested via web by Dana Vance...
scheduled by mistake
ELE16-03548 Final12/21/201612/22/201612/22/2016 9:55:41 AMAPASS
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn...

ok to final
ELE16-03906 Final12/22/201612/22/201612/22/2016 8:57:29 AMAPASS
ok to final permit...no corrections needed
ELE12-01902 ELE-Aging Inspection12/22/201612/22/201612/22/2016 8:45:58 AM DONE
still waiting on contractor to get access
ELE12-01900 ELE-Aging Inspection12/22/201612/22/201612/22/2016 8:45:24 AM DONE
still waiting on contractor to get access
ELE16-03374 Final12/21/201612/22/201612/22/2016 8:41:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Dana Vance....

ok to final
ELE16-04091 Final12/21/201612/22/201612/22/2016 8:27:47 AMAPASS
permanent service and final inspection for cable tv power supply alpha cabinet. at s.w. corner 7375 w.fairview behind starbucks. contact ####-#### andy. Phone #: ###-#### Inspection requested via web by andrew dopieralski...

ok to final
ELE16-04091 Permanent Service12/22/201612/22/201612/22/2016 8:27:20 AMAPASS
permanent service and final inspection for cable tv power supply alpha cabinet. at s.w. corner 7375 w.fairview behind starbucks. contact ####-#### andy. Phone #: ###-#### Inspection requested via web by andrew dopieralski...

p/s u/g n ok
ELE16-04092 Final12/21/201612/22/201612/22/2016 8:18:12 AMAPASS
permanent service and final inspection for cable tv power supply alpha cabinet at n.w. corner 1714 n. cole rd.behind axiom .contact ####-####. Phone #: ###-#### Inspection requested via web by andrew dopieralski...

ok to final
ELE16-04092 Permanent Service12/22/201612/22/201612/22/2016 8:17:47 AMAPASS
permanent service and final inspection for cable tv power supply alpha cabinet at n.w. corner 1714 n. cole rd.behind axiom .contact ####-####. Phone #: ###-#### Inspection requested via web by andrew dopieralski...

p/s u/g n ok