ELE17-04306
| Electrical Rough-In | 12/21/2017 | 12/22/2017 | 12/22/2017 3:01:43 PM | P | PASS |
|
|
wall rough Phone #: ###-#### Inspection requested via web by Bryan McLaughlin...ok to cover
|
ELE12-02903
| ELE-Aging Inspection | 12/22/2017 | 12/22/2017 | 12/22/2017 2:48:05 PM | | DONE |
|
|
Homeowner has been contacted to request final. No inspection requested at this time.
|
ELE13-03397
| Final | 12/22/2017 | 12/22/2017 | 12/22/2017 2:45:27 PM | P | PASS |
|
|
ok to final
|
ELE17-03417
| Final | 12/22/2017 | 12/22/2017 | 12/22/2017 2:43:06 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall...contractor has been notified multiple times for need of final inspection
|
ELE17-04307
| Rough-In Permanent Service | 12/22/2017 | 12/22/2017 | 12/22/2017 1:25:18 PM | P | PASS |
|
|
rough-in Phone #: ###-#### Inspection requested via web by cal crosby...rough in ok to cover...p/s u/g new ok
|
ELE17-03903
| Final | 12/21/2017 | 12/22/2017 | 12/22/2017 12:31:55 PM | P | PASS |
|
|
Justin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...ok to final
|
ELE17-03007
| Final | 12/21/2017 | 12/22/2017 | 12/22/2017 10:35:04 AM | A | FAIL |
|
|
Inspection requested via web by Larry Richardson... 1) lift pump outlet shall be gfi protected 2) breaker lock out needs installed on dishwasher circuit 3) breaker lockout needs installed on water heater circuit 4) w/p outlet shall have a in use heavy duty cover 5) service outlet is needed within 25' of back hvac unit
|
ELE17-03344
| Final | 12/21/2017 | 12/22/2017 | 12/22/2017 10:02:47 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Terry Scott...outlet on end of pennisula has no power...110.7
|
ELE17-03003
| Electrical Rough-In | 12/21/2017 | 12/22/2017 | 12/22/2017 9:29:59 AM | A | PASS |
|
|
Wall cover and service disconnect Phone #: ###-#### Inspection requested via web by cris flores....wall cover ok...p/s for relocation of disconnect ok
|
ELE17-03003
| Permanent Service | 12/22/2017 | 12/22/2017 | 12/22/2017 9:29:30 AM | A | PASS |
|
|
Wall cover and service disconnect Phone #: ###-#### Inspection requested via web by cris flores....p/s rec ok
|
ELE17-02789
| Electrical Rough-In | 12/21/2017 | 12/22/2017 | 12/22/2017 9:08:55 AM | A | PASS |
|
|
We are requesting a ufer ground inspection for tomorrow morning. Our contact is Rod @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate... uffer ground inspection and 2 parking lot light cages and grounding...ok
|
ELE17-02360
| Final | 12/21/2017 | 12/22/2017 | 12/22/2017 8:52:34 AM | A | PASS |
|
|
Contact is Jay Sprik. Phone #: ###-#### Inspection requested via web by Richard Montgomery...job complete...ok to final
|
ELE12-03014
| ELE-Aging Inspection | 12/22/2017 | 12/22/2017 | 12/22/2017 7:54:23 AM | | FAIL |
|
|
contractor has been contacted and has yet to scheduled a final
|
ELE17-03003
| Electrical Rough-In | 12/21/2017 | 12/22/2017 | 12/21/2017 12:07:43 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by cris flores Inspection cancelled from web by: cris flores
|