BLD97-00422
| INSP - Letter of compliance | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | | PASS |
|
|
/ / 316 - C/C # 014080
|
BLD97-00422
| INSP - Letter of compliance | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | | PASS |
|
|
/ / 316 - C/C # 014080
|
BLD97-02227
| INSP - Letter of compliance | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | | PASS |
|
|
/ / 316 - C/C # 014081
|
BLD97-02227
| INSP - Letter of compliance | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | | PASS |
|
|
/ / 316 - C/C # 014081
|
BLD97-02775
| INSP - Letter of compliance | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | | PASS |
|
|
/ / 316 - C/C # 014079
|
BLD97-02775
| INSP - Letter of compliance | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | | PASS |
|
|
/ / 316 - C/C # 014079
|
BLD97-03228
| INSP - Framing/Rough-in | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | FAIL |
|
|
12/22/97 316 - C/N...Garage fronts not as per engineering...
|
BLD97-03281
| INSP - Framing/Rough-in | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | PASS |
|
|
12/22/97 316 - OK
|
BLD97-03395
| INSP - Framing/Rough-in | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | FAIL |
|
|
12/22/97 316 - C/N...No author to insul...need plans and truss eng.....
|
BLD97-03639
| INSP - Footings | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | FAIL |
|
|
12/22/97 316 - Poured W/O inspection 9:30 AM....No approved plans.
|
MEC97-02337
| INSP - Final | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | FAIL |
|
|
12/22/97 316 - C/N...Prot post, fix holes..A/C..Condens, seal dryer vent
|
MEC97-02337
| INSP - Final | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | FAIL |
|
|
12/22/97 316 - C/N...Prot post, fix holes..A/C..Condens, seal dryer vent
|
MEC97-03789
| INSP - Framing/ Rough-in | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | A | PASS |
|
|
12/22/97 316 - Scheduled by Hello!.
|
BLD95-01102
| INSP - Temporary occupancy | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | FAIL |
|
|
12/23/97 316 - C/N....No approved plans or occupancy request form on sit
|
BLD97-00422
| INSP - Final | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PASS |
|
|
12/23/97 316 - C/C # 014080
|
BLD97-00704
| INSP - Temporary occupancy | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | FAIL |
|
|
12/23/97 316 - C/N...Shell...Need letter of approval from spec insp..Ins
|
BLD97-00742
| INSP - Carpentry | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PART |
|
|
12/23/97 316 - BLDG 3--FIRE CAULKING Preliminary insp of.......
|
BLD97-01398
| INSP - Framing/Rough-in | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PASS |
|
|
12/23/97 316 - Ceiling Grid OK
|
BLD97-02227
| INSP - Final | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PASS |
|
|
12/23/97 316 - C/C # 014081
|
BLD97-02775
| INSP - Final | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PASS |
|
|
12/23/97 316 - C/C # 014079
|
BLD97-02429
| INSP - Temporary occupancy | 12/23/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | FAIL |
|
|
12/23/97 316 - C/N left for shell and core....to be finalled prior to ca
|
BLD97-03176
| INSP - Framing/Rough-in | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PASS |
|
|
12/23/97 316 - RE-INSPECTION OK
|
BLD97-03176
| INSP - Energy code compliance | 12/22/1997 | 12/23/1997 | 12/23/1997 12:00:00 AM | P | PASS |
|
|
12/23/97 316 -
|