ELE05-04411
| Rough-In Permanent Service | 12/22/2005 | 12/23/2005 | 12/23/2005 1:36:54 PM | P | FAIL |
|
|
vivian ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie p/s ok see added p/s, cor. posted for r/i called BCC shall install all outside cans, complete all makeup inside and outside, 300.4 nail plates and 11/4" where required, high and low voltage cables
|
ELE05-04606
| Rough-In Permanent Service | 12/23/2005 | 12/23/2005 | 12/23/2005 12:06:33 PM | P | PASS |
|
|
ron ###-#### called protect romex within 6ft of attic access, remove low voltage from space for p/s r/i ok, p/s u/g new ok
|
ELE05-03440
| Final | 12/22/2005 | 12/23/2005 | 12/23/2005 10:17:11 AM | A | FAIL |
|
|
aaron; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa cor. posted to electrical and low voltage contractors, electrical 230.9&24(B) clearence of service drop by back deck, low voltage 110.26(F)(2) remove phone and tv cables from dedicated space below p/s called
|
ELE05-04258
| Electrical Rough-In | 12/22/2005 | 12/23/2005 | 12/23/2005 9:23:49 AM | A | FAIL |
|
|
lamar - no phone # Internet Inspection Request from: Letitia Mesa cor. met owner 210.12 afci for bed rms, 250.148 grd all metal boxes, 300.4 nail plates and 11/4",314.16 box fill, 300.14 6" free lenght, complete all makeup, 210.52(A) outlet spacing, 210.52(B&C) address wiring in kit. ,314.43 no screws or nails in plastic boxes,314.17 use approved connectors for romex, 240.24and BCC overcurrent devices higher than 6ft 7", update permit for work in 7rms not 2 rms, 10 days to correct violations , uncover all wiring covered before inspection, or power may be disconnected, if more violations created permit may be voided, and owner required to secure contractor staple romex within 8 or 12 inches of boxes, seal all unused KOs
|
ELE05-04411
| Permanent Service | 12/23/2005 | 12/23/2005 | 12/23/2005 12:00:00 AM | P | PASS |
|
|
vivian ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie p/s u/g new ok
|