ELE05-04605
| Electrical Rough-In | 12/23/2005 | 12/23/2005 | 12/23/2005 3:39:09 PM | P | PASS |
|
|
call 30 min prior to meet for access//tom falash; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called elect, said to add light sws before cover if they decide to. ric walls only
|
ELE05-03253
| Final | 12/22/2005 | 12/23/2005 | 12/23/2005 2:36:17 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 12/22/2005 at 2:00:09 PM. Contact: ###-####. called contr, left corr notice, 406.5 recpt faceplates shall cover opening and seat against mounting surface, 410.12 luminaire shall cover outlet box, 352.30 rnc shall be strapped within 3' of panel,110.26 sufficient access and working space shall be provided and maintained about elect equipment,110.26(A)(1)&(2) work space width and depth shall be provided, 250.104(A) metal water piping shall be bonded
|
ELE05-04024
| Final | 12/22/2005 | 12/23/2005 | 12/23/2005 10:32:53 AM | A | PASS |
|
|
For first thing in am if possible. Thanks!; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney ok to final
|
ELE05-04598
| Rough-In Permanent Service | 12/22/2005 | 12/23/2005 | 12/23/2005 9:56:37 AM | A | PASS |
|
|
ron ###-#### ric ok, p/s, u/g, n, ok
|
ELE05-04603
| Final | 12/22/2005 | 12/23/2005 | 12/23/2005 9:31:45 AM | A | PASS |
|
|
darrell ###-####///call to meet for access 20-30 min ok to final
|
ELE05-04386
| Electrical Rough-In | 12/22/2005 | 12/23/2005 | 12/23/2005 8:30:34 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 12/22/2005 at 1:17:08 PM. Contact: ###-####. ok to cover rest of clg
|
ELE05-04602
| Final | 12/22/2005 | 12/23/2005 | 12/23/2005 8:22:02 AM | A | NH |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer called contr, left message, no access
|