ELE13-00375
| ELE-Aging Inspection | 12/23/2014 | 12/23/2014 | 12/24/2014 11:20:49 AM | | CANC |
|
|
Will check after holiday
|
ELE14-03053
| Final | 12/23/2014 | 12/23/2014 | 12/23/2014 2:53:38 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by HZ ZAHIC Hot tub not set at time of final GFCI installed in hot tub disconnect. Final ok
|
ELE14-03027
| Final | 12/23/2014 | 12/23/2014 | 12/23/2014 2:18:54 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
|
ELE14-02848
| Final | 12/22/2014 | 12/23/2014 | 12/23/2014 1:35:20 PM | P | PASS |
|
|
Final Inspection Tues 23rd. Will meet at site 1:30pm. Tim. ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence Final ok
|
ELE14-03443
| Final | 12/22/2014 | 12/23/2014 | 12/23/2014 12:59:02 PM | P | PASS |
|
|
10 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, CSA, IEEE-1547, and UL-1741 listed. And 265 watt Suniva panels, ETL listed. A single home run, in conduit, is ran from solar array to the knife switch, located next to meter base on south side of home, next to garage door. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the solar circuit number identified in the knife switch and the panel schedule. The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode in main panel, and labeled.
The main panel is in the garage, so give the homeowner a call for access at 801.891.3603
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King Final ok
|
ELE14-03443
| Electrical Rough-In | 12/23/2014 | 12/23/2014 | 12/23/2014 12:53:43 PM | P | PASS |
|
|
10 solar panels. AC micro-inverter system. No DC voltage. Enphase M250 Micro-Inverters, CSA, IEEE-1547, and UL-1741 listed. And 265 watt Suniva panels, ETL listed. A single home run, in conduit, is ran from solar array to the knife switch, located next to meter base on south side of home, next to garage door. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the solar circuit number identified in the knife switch and the panel schedule. The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode in main panel, and labeled.
The main panel is in the garage, so give the homeowner a call for access at 801.891.3603
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King Rough in ok cover
|
GCE14-00218
| GCE-Rough-In | 12/23/2014 | 12/23/2014 | 12/23/2014 12:21:39 PM | P | PASS |
|
|
TDR Electric ###-#### - underground insp. Under slab rough in ok cover
|
GCE14-00217
| GCE-Rough-In | 12/23/2014 | 12/23/2014 | 12/23/2014 12:21:07 PM | P | PASS |
|
|
TDR Electric ###-#### - underground insp. Under slab rough in ok cover
|
ELE14-03435
| Final | 12/22/2014 | 12/23/2014 | 12/23/2014 9:37:12 AM | A | PASS |
|
|
Gary Phone #: ###-#### Final ok
|
ELE14-03239
| Electrical Rough-In | 12/17/2014 | 12/23/2014 | 12/23/2014 9:35:04 AM | A | CANC |
|
|
Area outside of building footprints Phone #: ###-#### >> Inspection requested via web by Lori Stout Inspection cancelled from web by: Lori Stout
|
ELE14-03284
| Final | 12/22/2014 | 12/23/2014 | 12/23/2014 8:37:03 AM | A | PASS |
|
|
Kyle Phone #: ###-#### Final ok
|