Inspections for the day of: Tuesday, December 23, 2014.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00375 ELE-Aging Inspection12/23/201412/23/201412/24/2014 11:20:49 AM CANC
Will check after holiday
ELE14-03053 Final12/23/201412/23/201412/23/2014 2:53:38 PMPPASS
Phone #: ###-#### Inspection requested via web by HZ ZAHIC Hot tub not set at time of final GFCI installed in hot tub disconnect. Final ok
ELE14-03027 Final12/23/201412/23/201412/23/2014 2:18:54 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
ELE14-02848 Final12/22/201412/23/201412/23/2014 1:35:20 PMPPASS
Final Inspection Tues 23rd. Will meet at site 1:30pm. Tim. ###-#### Phone #: ###-#### Inspection requested via web by Tim Lawrence Final ok
ELE14-03443 Final12/22/201412/23/201412/23/2014 12:59:02 PMPPASS
10 solar panels.
AC micro-inverter system. No DC voltage.
Enphase M250 Micro-Inverters, CSA, IEEE-1547, and UL-1741 listed.
And 265 watt Suniva panels, ETL listed.
A single home run, in conduit, is ran from solar array to the knife switch, located next to meter base on south side of home, next to garage door. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the solar circuit number identified in the knife switch and the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode in main panel, and labeled.

The main panel is in the garage, so give the homeowner a call for access at 801.891.3603

Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King Final ok
ELE14-03443 Electrical Rough-In12/23/201412/23/201412/23/2014 12:53:43 PMPPASS
10 solar panels.
AC micro-inverter system. No DC voltage.
Enphase M250 Micro-Inverters, CSA, IEEE-1547, and UL-1741 listed.
And 265 watt Suniva panels, ETL listed.
A single home run, in conduit, is ran from solar array to the knife switch, located next to meter base on south side of home, next to garage door. From the knife switch to breaker in main panel, at the top of the busing, opposite the feeder lugs. The solar breaker and the knife switch are clearly marked for solar, and the solar circuit number identified in the knife switch and the panel schedule.
The inverters, panels and rails are all bonded with a number 6 ground that runs back to the service electrode in main panel, and labeled.

The main panel is in the garage, so give the homeowner a call for access at 801.891.3603

Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King Rough in ok cover
GCE14-00218 GCE-Rough-In12/23/201412/23/201412/23/2014 12:21:39 PMPPASS
TDR Electric ###-#### - underground insp. Under slab rough in ok cover
GCE14-00217 GCE-Rough-In12/23/201412/23/201412/23/2014 12:21:07 PMPPASS
TDR Electric ###-#### - underground insp. Under slab rough in ok cover
ELE14-03435 Final12/22/201412/23/201412/23/2014 9:37:12 AMAPASS
Gary Phone #: ###-#### Final ok
ELE14-03239 Electrical Rough-In12/17/201412/23/201412/23/2014 9:35:04 AMACANC
Area outside of building footprints Phone #: ###-#### >> Inspection requested via web by Lori Stout Inspection cancelled from web by: Lori Stout
ELE14-03284 Final12/22/201412/23/201412/23/2014 8:37:03 AMAPASS
Kyle Phone #: ###-#### Final ok