Inspections
/
Inspector Activity
Inspections for the day of:
Wednesday, December 23, 2015
.
Number of inspections:
21
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Andy J. Long
Title
EROSION INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC15-00468
General Inspection
12/23/2015
12/23/2015
12/24/2015 11:18:59 AM
CANC
ESC15-00702
General Inspection
12/22/2015
12/23/2015
12/24/2015 11:18:48 AM
A
CANC
rescheduled
ESC15-00306
General Inspection
12/22/2015
12/23/2015
12/23/2015 3:23:02 PM
A
PASS
No activity at site. No changes to overall site dewatering set up.
No trackout, no issues with perimeter sediment controls. Approved.
ESC15-00096
Aging Inspection
12/23/2015
12/23/2015
12/23/2015 2:37:47 PM
PASS
ESC14-01151
General Inspection
12/23/2015
12/23/2015
12/23/2015 1:36:14 PM
CANC
ESC11-00879
General Inspection
12/23/2015
12/23/2015
12/23/2015 1:35:54 PM
PASS
ESC15-00782
Site Final
12/23/2015
12/23/2015
12/23/2015 1:03:20 PM
P
PASS
Work complete. No temp BMP inlet filters on Broadway MS4. No outstanding corrections or stabilization required. Tenants already occuping space.
Permit finaled.
ESC15-01240
Site Final
12/22/2015
12/23/2015
12/23/2015 12:19:11 PM
A
PASS
Call me 30 minutes prior to inspection if you would like me to meet you there. Phone #: ###-#### Inspection requested via web by Eldon Oyadomari
Project complete and cleaned up.
ESC15-01240
DOC - Permit Finaled
12/23/2015
12/23/2015
12/23/2015 12:18:48 PM
P
PASS
ESC15-00463
General Inspection
12/23/2015
12/23/2015
12/23/2015 12:16:40 PM
CANC
ESC15-01049
Site Final
12/22/2015
12/23/2015
12/23/2015 12:09:38 PM
A
PASS
Work complete. Parking lot and stormwater infrastructure complete. Temp BMPs removed. ESC conditions satisfied.
ESC15-00789
Aging Inspection
12/23/2015
12/23/2015
12/23/2015 11:41:54 AM
PASS
No trackout from Afton site. WIP on utility and foundation. No corrections at this this time. BMPs installed.
ESC14-00588
General Inspection
12/23/2015
12/23/2015
12/23/2015 11:21:54 AM
A
PASS
WIP on vertical construciton. Trackout controls and site perimeter sediment controls are working well to keep dirt on site. No discharges observed or reported.
Approved, no corrections at this time.
ESC15-01283
Site Preparation
12/23/2015
12/23/2015
12/23/2015 11:19:59 AM
P
PEND
Corrections in progress.
BMPs in place:
- permit sign now posted clearly
- lined concrete washout
- road in front of lot has been swept
Corrections remaining:
- trench in wattles in the upper and lower
discharge points above and below rock staging/parking area
- place 1-2 gravel bag check dams to capture any loose sediment/sand in runoff from site. Water flows down street to open vegetated lot before reaching Highland View Drive.
- noted that much of the trackout initially observed is actually an existing mixture of leaves and sand, not related to construction. This could have been discussed in the Site Prep inspection that was not called in.
Note
- Special Investigation Fee issued by Evan Jenkins due to issues responded to 12/18 and 12/21, 12/22.
- Stop Work Order was issued and work continued simultaneously with corrective action work.
- Reinspection fee issued due to Site Preparation inspection needed to remove SWO tag on site.
Fines are be due by January 8th 2016.
GC Travis Perry needs to renew RP license.
Parcel tag and SWO removed, will inspect at end of day for clean up and completion of corrections listed above.
ESC15-01224
Site Preparation
12/22/2015
12/23/2015
12/23/2015 11:06:03 AM
A
PASS
Bruce Phone #: ###-####
Site walk through and SWPPP review with RP Bruce and project manager Dennis with CM Company.
BMPs installed/implemented include perimter sediment control wattles, rock construction entrance with rumble bars to prevent tracking, a SWPPP binder on site with regular inspections. Ecopan concrete washout will be utilized for concrete work at site. Not yet on site.
Dewatering plan has been included in SWPPP with groundwater predicted to be at 5-9 feet at time of utility and foundation work. Current plan calls for pumping water into the irrigation canal that runs underground along the north side of site. Additional turbidity reduction measures are listed if needed as well as discharging into an onsite swale.
Construction to begin after beginning of the year.
Approved.
ESC15-00496
General Inspection
12/23/2015
12/23/2015
12/23/2015 8:51:15 AM
PASS
Some minor work remaining. No activity at time of inspection. No violations observed.
ESC13-01159
General Inspection
12/23/2015
12/23/2015
12/23/2015 8:17:55 AM
CANC
ESC15-00598
Aging Inspection
12/23/2015
12/23/2015
12/23/2015 8:06:00 AM
DONE
ESC15-00598
DOC - Permit Finaled
12/23/2015
12/23/2015
12/23/2015 8:05:47 AM
P
PASS
Permit already finaled.
ESC15-00596
Aging Inspection
12/23/2015
12/23/2015
12/23/2015 8:03:45 AM
CANC
ESC15-01004
Site Preparation
12/22/2015
12/23/2015
12/22/2015 10:28:56 AM
A
PART
Call JIm ###-#### if you have questions
Site preveiously prepped and is approved for staging for footing work to begin in early January. Tuffy and Big D excavation on site.
Corrections:
- install 1 DI bag on Myrtle and 6th to receive runoff from Broad Street east of construction by Trader Joes. All of DIs have inlet protection.
- site is already pit run should not be too muddy, but construction entrance may require additional rock or rumble bars.
VM left Jim, discussed BMps with Dustin. Awaiting call from Jim.