ELE13-02874
| Final | 12/23/2013 | 12/24/2013 | 12/24/2013 12:52:48 PM | P | FAIL |
|
|
Donald Phone #: ###-#### 408.4- Every circuit shall be legibly identified. 406.8(B)- 15 and 20 amp 120 volt receptical outlets installed outdoors shall be weather resistant type. 210.8- All 15 and 20 amp receptical outlets installed outside shall have GFCI protection. 110.3(B)- Devices not installed as per manufactureds instructions, GFI outlet lin/ load reversed, and reversed polarity, dead outlets. 210.8- receptical outlets installed to serve counter top in kitchen shall have GFCI protection. 314.25- All boxes shall have covers. 210.11(C)(3)- Bathroom recepticals shall be installed on a 20 amp circuit and shall not feed other outlets. 300.4- NM cable in garage shall not be secured less than 1 1/4" from framing surface. 340.12(10)- Type UF cable shall not be installed where subject to physical damage. 210.8- Garage 15 and 20 amp recepticals shall have GFCI protection.
|
MIS13-00336
| ELE-Conference | 12/23/2013 | 12/24/2013 | 12/24/2013 10:48:15 AM | A | DONE |
|
|
report from inspector 411 doing electrical and plumbing work, no permit. Stopped by, sign on door wet floors, no answer at door
|
ELE13-03191
| Final | 12/24/2013 | 12/24/2013 | 12/24/2013 10:33:35 AM | P | NR |
|
|
Their asking for a ceiling inspection I''d like to final as much as possible I believe the building is ready thanks Brad Phone #: ###-#### >> Inspection requested via web by Brad Baker
|
ELE13-03191
| Electrical Rough-In | 12/24/2013 | 12/24/2013 | 12/24/2013 10:31:16 AM | P | PASS |
|
|
Their asking for a ceiling inspection I''d like to final as much as possible I believe the building is ready thanks Brad Phone #: ###-#### >> Inspection requested via web by Brad Baker Ceiling rough in ok cover
|
ELE13-03358
| Final | 12/23/2013 | 12/24/2013 | 12/24/2013 10:14:16 AM | A | PASS |
|
|
This will be for a final inspection. Please contact Justin Metcalf ###-#### before arrival to meet you there. Thank you and happy holidays Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Final ok
|
ELE13-03389
| Final | 12/23/2013 | 12/24/2013 | 12/24/2013 10:03:47 AM | A | PASS |
|
|
THE WHIPS ARE INSTALLED. IM DONE COMPLETELY. Phone #: ###-#### >> Inspection requested via web by MARK PINNEY Final ok
|
ELE04-02374
| Final | 12/24/2013 | 12/24/2013 | 12/24/2013 9:35:21 AM | P | PASS |
|
|
Corrections completed on permit ele13-03542. Final ok
|
ELE13-03542
| Final | 12/23/2013 | 12/24/2013 | 12/24/2013 9:33:40 AM | A | PASS |
|
|
Contact: Marty Vanness Phone #: ###-#### >> Inspection requested via web by Deb Gooden Corretions for ele04-02374 Final ok
|
ELE13-03358
| Electrical Rough-In | 12/23/2013 | 12/24/2013 | 12/24/2013 9:16:29 AM | A | PASS |
|
|
This will be a rough in inspection. Please contact Justin Metcalf ###-#### before arrival to meet you there. Thank you and have a great day Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Rough in ok
|
ELE13-03519
| Temporary Service | 12/23/2013 | 12/24/2013 | 12/23/2013 3:02:38 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Duplicate request t/s u/g n ok
|
ELE13-03519
| Temporary Service | 12/23/2013 | 12/24/2013 | 12/23/2013 3:01:58 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI t/s u/g n ok
|