Inspections for the day of: Tuesday, December 24, 2019.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05609 Final12/23/201912/24/201912/24/2019 2:16:49 PMPFAIL
after 1:30 please - Phone #: ###-#### Inspection requested via web by Aaron Alandt - no access to equipment
PLM19-05387 Final12/23/201912/24/201912/24/2019 2:16:21 PMPFAIL
after 1:30 please Phone #: ###-#### Inspection requested via web by Aaron Alandt - no access to equipment
MEC19-04663 Final12/19/201912/24/201912/24/2019 1:09:20 PMPPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
MEC19-05758 Final12/23/201912/24/201912/24/2019 12:37:19 PMPFAIL
Please inspect early PM and call Jeremy on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - Not allowed to use building cavities as ducts or plenums. Need to run a duct in the joist space for returns in bedrooms. This should be scheduled as a rough in inspection because we will need to verify combustion air opening in mechanical room for a final.
MEC19-05054 Final12/23/201912/24/201912/24/2019 9:32:34 AMAPASS
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
MEC19-05201 Rough-in12/23/201912/24/201912/24/2019 7:27:45 AMAPASS
Weld light test, please call Brad at least 30 min prior to inspection, thank you, Merry Christmas! Phone #: ###-#### Inspection requested via web by Rhonda Marcum - Light test for offset and vertical drops okay