Inspections for the day of: Thursday, December 27, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00558 Conference12/27/200712/27/200712/28/2007 2:38:25 PMPDONE
eric Phone #: ###-#### met owner , talked about in-use covers, strapping risers, bond screw, outside gfci, kitchen gfci, dead receptacles, open neutrals, open grounds, closet lights, abandon wire not used, flush switch plates, heater disconnect,flex over nm cable, staple nm cable at heater area, finish install lights, switches, dead receptacles, afci for bedrooms, if move in, allow 3' clear space around walls for inspection, owner made list of items
ELE07-03763 Final12/27/200712/27/200712/27/2007 3:21:05 PMPPASS
mike Phone #: ###-#### ok to final, signed occupancy card
ELE07-03763 Electrical Rough-In12/27/200712/27/200712/27/2007 3:02:13 PMPPASS
mike Phone #: ###-#### corrections made, ok to cover ceiling
ELE07-04212 Permanent Service12/27/200712/27/200712/27/2007 2:15:08 PMPPASS
james Phone #: ###-#### met contractor, told them that they need to call for am inspection, they assuming ok for power to reconnect before full inspection. contractor did not start work until after 12:30 pm. p/s o/h rec ok
ELE07-00558 Final12/26/200712/27/200712/27/2007 1:36:47 PMPCANC
eric Phone #: ###-#### see conference
ELE07-03638 Final12/27/200712/27/200712/27/2007 12:51:06 PMPPASS
michael Phone #: ###-#### ok to final
ELE07-04185 Final12/26/200712/27/200712/27/2007 10:59:06 AMAFAIL
scott Phone #: ###-#### called contr, left correction notice, nec 408.4 circuit directory shall be clear, concise and explanatory for each circuit, 110.12(A) unused openings shall be closed in panel, 334.30 nm cable shall be stapled within 12" of box, 314.23(A) boxes shall be securely mounted, 314.25 boxes shall have cover installed
ELE07-04202 Electrical Rough-In12/26/200712/27/200712/27/2007 9:54:01 AMAPASS
jay Note: please call for access Phone #: ###-#### corrections made, ric ok
ELE07-04210 Electrical Rough-In12/26/200712/27/200712/27/2007 9:20:53 AMAPASS
Need Electrical Rough in Thanks Phone #: ###-#### Internet Inspection Request from: Lynn Cable ric ok
ELE07-04210 Permanent Service12/27/200712/27/200712/27/2007 9:10:20 AMAPASS
Need Electrical Rough in Thanks Phone #: ###-#### Internet Inspection Request from: Lynn Cable p/s u/g n ok
ELE07-03252 Electrical Rough-In12/26/200712/27/200712/27/2007 8:42:07 AMAPASS
mark Note: 1st thing is possible Phone #: ###-#### corrections made, ok to final