Inspections for the day of: Wednesday, December 28, 2011.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02846 Electrical Rough-In12/27/201112/28/201112/28/2011 1:50:48 PMPFAIL
Job is complete. Please final. someone will be home. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan called, shall bond downspout, provide gfci withi 20' of tub, show where listing sticker is located
ELE11-02886 Permanent Service12/27/201112/28/201112/28/2011 12:09:50 PMPPASS
Paul Phone #: ###-#### >> Inspection requested via web by Sean DeLacy p/s u/g rec ok
ELE11-02775 Electrical Rough-In12/27/201112/28/201112/28/2011 11:36:45 AMPPASS
Need approval to cover wiring for mail box light. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ri ok
ELE11-02722 Rough-In Permanent Service12/28/201112/28/201112/28/2011 10:16:40 AMPPASS
Please contact Cody ###-#### with any concerns Phone #: ###-#### >> Inspection requested via web by Tracy Robertson ri ok, p/s u/g n ok
GCE11-00151 GCE-Final12/27/201112/28/201112/28/2011 9:14:55 AMANR
Todd @ ###-####Call in advance - AM Inspection see fail p/s
GCE11-00151 GCE-Permanent Service12/27/201112/28/201112/28/2011 9:13:37 AMAFAIL
Todd @ ###-####Call in advance - AM Inspection called, left correction notice, NEC250.56 shall augment grounding electrode with 1 additional rod if less than 25 ohms, BCC shall identify all service disconnects and sub-panels, shall provide access to sub-panels and provide conductors and fuses
ELE11-02892 Electrical Rough-In12/28/201112/28/201112/28/2011 8:12:15 AMAPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER ri ok
ELE11-02892 Final12/28/201112/28/201112/28/2011 8:12:05 AMAPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER ok final