Inspections for the day of: Wednesday, December 28, 2016.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-04216 Final12/28/201612/28/201612/28/2016 3:05:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Cathy Campbell
MEC16-05702 Pressure Test12/28/201612/28/201612/28/2016 2:17:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Aaron Toomey
20lb gas, 5lb flue
MEC16-05702 Rough-in12/28/201612/28/201612/28/2016 2:15:25 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aaron Toomey
exhaust duct needs to be sealed,
romex in return transfer
gas flex needs approved hangers
MEC16-04686 Final12/28/201612/28/201612/28/2016 1:52:05 PMPPASS
Oleg Phone #: ###-####
MEC16-05543 Rough-in12/27/201612/28/201612/28/2016 1:32:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
rough in needs to match manual j
returns for bedrooms
MEC16-05543 Pressure Test12/27/201612/28/201612/28/2016 1:27:10 PMPPART
Phone #: ###-#### Inspection requested via web by Bryan Palmer
5lb flue ok
gas pressure at 0
MEC16-05765 Final12/28/201612/28/201612/28/2016 1:06:46 PMPPASS
Would like early PM. and a call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
MEC16-04896 Rough-in12/27/201612/28/201612/28/2016 10:50:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
need to fire caulk between draft stop and bvent
MEC16-04787 Final12/27/201612/28/201612/28/2016 10:02:19 AMAFAIL
Return air floor register is not installed yet. Everything else is complete. Please call the contractor, Larry ###-#### or Max with our shop, ###-#### for door code. Thanks! Inspection requested via web by Floyd Floyd Peek
need balance report, gas piping needs sediment traps before furnace, and water heater, armaflex needs uv protection
MEC16-05755 Pressure Test12/27/201612/28/201612/28/2016 9:40:03 AMAPASS
Philip Phone #: ###-####
20lb gas
MEC16-05758 Rough-in12/27/201612/28/201612/28/2016 9:23:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC16-05757 Rough-in12/27/201612/28/201612/28/2016 9:23:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC16-04871 Rough-in12/27/201612/28/201612/28/2016 8:56:24 AMPPASS
Phone #: ###-#### Inspection requested via web by Cathy Campbell
MEC16-04871 Pressure Test12/27/201612/28/201612/28/2016 8:56:03 AMPPASS
Phone #: ###-#### Inspection requested via web by Cathy Campbell
60,20lb gas
5lb flue
MEC16-05689 Rough-in12/27/201612/28/201612/28/2016 8:48:48 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC16-05685 Rough-in12/27/201612/28/201612/28/2016 8:42:30 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC16-04704 Final12/27/201612/28/201612/28/2016 8:39:40 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC16-05753 Final12/27/201612/28/201612/28/2016 12:00:00 AMPCANC
Steve is the homeowner and will be meeting you on site. Please give him 15-30 minute notice, his number is ###-####. Phone #: ###-#### >> Inspection requested via web by Rick Montgomery