Inspections for the day of: Thursday, December 28, 2017.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-05772 Final12/26/201712/28/201712/28/2017 4:26:29 PMPPASS
PLEASE CALL INSTALLER, DWIGHT, BEFORE ARRIVAL TO ENSURE JOB COMPLETION ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
MEC17-01960 Mec-Aging Inspection12/28/201712/28/201712/28/2017 3:31:24 PM CANC
MEC17-05809 Pressure Test12/28/201712/28/201712/28/2017 3:08:40 PMPPASS
Inspection requested via web by Floyd Floyd Peek - 20lb gas
MEC17-05808 Pressure Test12/28/201712/28/201712/28/2017 3:08:05 PMPPASS
THANKS! Inspection requested via web by Floyd Floyd Peek - 20lb gas
MEC17-05365 Final12/27/201712/28/201712/28/2017 2:25:46 PMPPASS
Area should be unlocked, please call technician if there''s any questions regarding access ###-#### Codie Coombs. Phone #: ###-#### Inspection requested via web by Melissa Skinner
MEC17-05794 Pressure Test12/27/201712/28/201712/28/2017 2:07:55 PMPFAIL
Phone #: ###-#### Inspection requested via web by Michael Kampe - Wrong gauge, need to presure test with 20lbs on a 30lb gauge for low pressure, or 60lbs on a 100lb gauge for medium and high pressure
MEC17-05698 Rough-in12/27/201712/28/201712/28/2017 10:16:28 AMAFAIL
we passed the pressure test on this job but failed the manual J. Phone #: ###-#### Inspection requested via web by Devony Bullard-
1) Need approved copy of manaul J on site
2) Missing nail plates on dryer duct, and lineset
3) Need a ladder on site to access equipment in attic
4) Missing fresh air to return plenum
5) Need a solid floor walk way from attic access to equipment platform thats not less then 24" wide
MEC17-05697 Rough-in12/27/201712/28/201712/28/2017 10:15:35 AMAFAIL
We failed pressure test and manual J Phone #: ###-#### Inspection requested via web by Devony Bullard-
1) Need approved copy of manaul J on site
2) Missing nail plates on dryer duct
3) Need a ladder on site to access equipment in attic
4) Missing fresh air to return plenum
5) Need a solid floor walk way from attic access to equipment platform thats not less then 24" wide
MEC17-05697 Pressure Test12/28/201712/28/201712/28/2017 10:12:23 AMAPASS
We failed pressure test and manual J Phone #: ###-#### Inspection requested via web by Devony Bullard - 20lb gas