MEC17-05772
| Final | 12/26/2017 | 12/28/2017 | 12/28/2017 4:26:29 PM | P | PASS |
|
|
PLEASE CALL INSTALLER, DWIGHT, BEFORE ARRIVAL TO ENSURE JOB COMPLETION ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
|
MEC17-01960
| Mec-Aging Inspection | 12/28/2017 | 12/28/2017 | 12/28/2017 3:31:24 PM | | CANC |
|
|
|
MEC17-05809
| Pressure Test | 12/28/2017 | 12/28/2017 | 12/28/2017 3:08:40 PM | P | PASS |
|
|
Inspection requested via web by Floyd Floyd Peek - 20lb gas
|
MEC17-05808
| Pressure Test | 12/28/2017 | 12/28/2017 | 12/28/2017 3:08:05 PM | P | PASS |
|
|
THANKS! Inspection requested via web by Floyd Floyd Peek - 20lb gas
|
MEC17-05365
| Final | 12/27/2017 | 12/28/2017 | 12/28/2017 2:25:46 PM | P | PASS |
|
|
Area should be unlocked, please call technician if there''s any questions regarding access ###-#### Codie Coombs. Phone #: ###-#### Inspection requested via web by Melissa Skinner
|
MEC17-05794
| Pressure Test | 12/27/2017 | 12/28/2017 | 12/28/2017 2:07:55 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Michael Kampe - Wrong gauge, need to presure test with 20lbs on a 30lb gauge for low pressure, or 60lbs on a 100lb gauge for medium and high pressure
|
MEC17-05698
| Rough-in | 12/27/2017 | 12/28/2017 | 12/28/2017 10:16:28 AM | A | FAIL |
|
|
we passed the pressure test on this job but failed the manual J. Phone #: ###-#### Inspection requested via web by Devony Bullard- 1) Need approved copy of manaul J on site 2) Missing nail plates on dryer duct, and lineset 3) Need a ladder on site to access equipment in attic 4) Missing fresh air to return plenum 5) Need a solid floor walk way from attic access to equipment platform thats not less then 24" wide
|
MEC17-05697
| Rough-in | 12/27/2017 | 12/28/2017 | 12/28/2017 10:15:35 AM | A | FAIL |
|
|
We failed pressure test and manual J Phone #: ###-#### Inspection requested via web by Devony Bullard- 1) Need approved copy of manaul J on site 2) Missing nail plates on dryer duct 3) Need a ladder on site to access equipment in attic 4) Missing fresh air to return plenum 5) Need a solid floor walk way from attic access to equipment platform thats not less then 24" wide
|
MEC17-05697
| Pressure Test | 12/28/2017 | 12/28/2017 | 12/28/2017 10:12:23 AM | A | PASS |
|
|
We failed pressure test and manual J Phone #: ###-#### Inspection requested via web by Devony Bullard - 20lb gas
|