Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-06069 Final12/27/201812/28/201812/28/2018 4:20:37 PMPPASS
Please call Dave prior to arrival ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil ducting co ok
MEC18-06121 Rough-in12/27/201812/28/201812/28/2018 3:41:04 PMPFAIL
GARAGE CODE 1022 Phone #: ###-#### Inspection requested via web by Oleg Chervak- needs weather tight electrical whip at condenser location- needs secondary drain ran to garage floor with no offset- need to insulate R/A to R-6 in garage- need 3 screws in all flue joints some are missing- recall in when corrections are made
MEC18-05903 Pressure Test12/28/201812/28/201812/28/2018 2:58:48 PMPPASS
The inspector has already been given permission by owner to enter the garage to whiteness the test. Contact the contractor Greg Bouwer at ###-#### for any questions about gaining entrance. Phone #: ###-#### Inspection requested via web by David Dixon- 60lb gas pass- tagged gas line at meter bar- will need to see drip leg after shut off valve but before regulator and need to secure csst above unit heater flue vent with 6" clearance to csst by final- call in final when ready
MEC18-05760 Final12/28/201812/28/201812/28/2018 2:29:28 PMPPASS
Josh ###-####- furnace co ok
MEC18-05547 Final12/28/201812/28/201812/28/2018 1:52:15 PMPPASS
Inspection requested via web by Andrea Grigsby- furnace a/c coil co ok
MEC18-06098 Final12/26/201812/28/201812/28/2018 1:19:07 PMPPASS
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- gas piping unit heater ok
MEC18-06098 Pressure Test12/26/201812/28/201812/28/2018 1:18:20 PMPPASS
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass
MEC18-06048 Final12/21/201812/28/201812/28/2018 11:47:26 AMAPASS
Please call Bruce or Janice Carruthers (###-####) 30 minutes prior to showing up,
Thank you. Phone #: ###-#### Inspection requested via web by Tyler Collado- furnace co ok
MEC18-05698 Rough-in12/27/201812/28/201812/28/2018 11:27:01 AMAFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley- missing transfers path for R/A both units to bedrooms
MEC18-05698 Pressure Test12/28/201812/28/201812/28/2018 11:26:26 AMAPASS
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass both units
MEC18-06116 Pressure Test12/28/201812/28/201812/28/2018 11:25:45 AMAPASS
20lb gas pass both units
MEC18-06116 Rough-in12/27/201812/28/201812/28/2018 11:25:16 AMAFAIL
Phone #: ###-#### Inspection requested via web by Terek Worley- missing transfer grills both units for R/A paths
MEC18-06001 Pressure Test12/27/201812/28/201812/28/2018 10:01:03 AMANR
Rose ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- gas piping is not installed into fireplace looks like needs to be routed to other side- need to retest when installed- need to add other to permit for all ducting installed- need to submit manual j for approval- recall in gas test and R/I when ready
MEC18-05664 Final12/28/201812/28/201812/28/2018 9:17:30 AMAPASS
josh ###-####- furnace co ok
MEC18-06105 Rough-in12/27/201812/28/201812/28/2018 8:43:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
MEC17-03358 Mec-Aging Inspection12/28/201812/28/201812/28/2018 8:17:27 AM CANC
MEC17-03358 DOC - Permit Expired12/28/201812/28/201812/28/2018 8:17:21 AMAPASS
no calls
MEC18-01369 Mec-Aging Inspection12/28/201812/28/201812/28/2018 8:16:59 AM FAIL
still need corrections made to fireplace to final this permit out