Inspections for the day of: Friday, December 29, 2017.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-04236 Electrical Rough-In12/28/201712/29/201712/29/2017 2:16:32 PMPPASS
There will be guys there. Call Aaron with any questions please ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan
Master bed, bath and powder bath rough in ok cover
ELE17-04345 Final12/28/201712/29/201712/29/2017 1:38:36 PMPFAIL
Any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller
300.4(B)(1)- Nonmetallic-Sheathed Cable. In both exposed and concealed locations where nonmetallic-sheathed cables pass
through either factory- or field-punched, cut, or drilled slots or holes in metal members, the cable shall be protected by listed
bushings or listed grommets covering all metal edges that are securely fastened in the opening prior to installation of the
cable. Where NM enters panel.
334.12(B)(4)- NM cables shall not be installed In wet or damp locations. Inside outdoor or underground raceways concidered wet location
Owner had to leave, put correction on meter base.
ELE17-04181 Rough-In Permanent Service12/28/201712/29/201712/29/2017 12:59:39 PMPPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon
Rough in ok cover p/s u/g n ok
ELE17-03182 Final12/28/201712/29/201712/29/2017 10:50:44 AMAPASS
garage code 0724 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
ELE17-04339 Rough-In Permanent Service12/28/201712/29/201712/29/2017 10:15:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok
ELE17-04280 Rough-In Permanent Service12/28/201712/29/201712/29/2017 9:44:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok
ELE17-03246 Final12/29/201712/29/201712/29/2017 8:47:21 AMAPASS
bodovino channel letters open faced neon.
Phone #: ###-#### Inspection requested via web by Dana Vance
Final ok
ELE17-03246 Electrical Rough-In12/29/201712/29/201712/29/2017 8:47:16 AMPPASS
bodovino channel letters open faced neon.
Phone #: ###-#### Inspection requested via web by Dana Vance
Listing and disconnecting means confirmed Rough in ok