ELE17-04236
| Electrical Rough-In | 12/28/2017 | 12/29/2017 | 12/29/2017 2:16:32 PM | P | PASS |
|
|
There will be guys there. Call Aaron with any questions please ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clay Morgan Master bed, bath and powder bath rough in ok cover
|
ELE17-04345
| Final | 12/28/2017 | 12/29/2017 | 12/29/2017 1:38:36 PM | P | FAIL |
|
|
Any questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller 300.4(B)(1)- Nonmetallic-Sheathed Cable. In both exposed and concealed locations where nonmetallic-sheathed cables pass through either factory- or field-punched, cut, or drilled slots or holes in metal members, the cable shall be protected by listed bushings or listed grommets covering all metal edges that are securely fastened in the opening prior to installation of the cable. Where NM enters panel. 334.12(B)(4)- NM cables shall not be installed In wet or damp locations. Inside outdoor or underground raceways concidered wet location Owner had to leave, put correction on meter base.
|
ELE17-04181
| Rough-In Permanent Service | 12/28/2017 | 12/29/2017 | 12/29/2017 12:59:39 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon Rough in ok cover p/s u/g n ok
|
ELE17-03182
| Final | 12/28/2017 | 12/29/2017 | 12/29/2017 10:50:44 AM | A | PASS |
|
|
garage code 0724 Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
ELE17-04339
| Rough-In Permanent Service | 12/28/2017 | 12/29/2017 | 12/29/2017 10:15:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE17-04280
| Rough-In Permanent Service | 12/28/2017 | 12/29/2017 | 12/29/2017 9:44:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE17-03246
| Final | 12/29/2017 | 12/29/2017 | 12/29/2017 8:47:21 AM | A | PASS |
|
|
bodovino channel letters open faced neon. Phone #: ###-#### Inspection requested via web by Dana Vance Final ok
|
ELE17-03246
| Electrical Rough-In | 12/29/2017 | 12/29/2017 | 12/29/2017 8:47:16 AM | P | PASS |
|
|
bodovino channel letters open faced neon. Phone #: ###-#### Inspection requested via web by Dana Vance Listing and disconnecting means confirmed Rough in ok
|