ELE07-00487
| ELE-Aging Inspection | 12/3/2007 | 12/3/2007 | 12/6/2007 9:55:39 AM | | PART |
|
|
wsuc waiting for contr to call
|
ELE07-02982
| Final | 12/3/2007 | 12/3/2007 | 12/3/2007 4:25:49 PM | P | FAIL |
|
|
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson called left message needs clearence downstairs closet lights
|
ELE07-03989
| Final | 12/3/2007 | 12/3/2007 | 12/3/2007 3:39:10 PM | P | PASS |
|
|
tom Phone #: ###-####
|
ELE06-04453
| Final | 12/3/2007 | 12/3/2007 | 12/3/2007 3:13:43 PM | P | PASS |
|
|
Loren, please call 1sr for access; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok
|
ELE07-03789
| Electrical Rough-In | 12/3/2007 | 12/3/2007 | 12/3/2007 2:47:16 PM | P | FAIL |
|
|
dale Note: please call 1/2 hr prior to inpsection so he show where to see Phone #: ###-#### corr called 300.4 nail plates, 300.14 needs 6" free length, 110.14(B) needs splicing devices wires just twisted together, 210.70 lights for outside exits, and accessible attic, 110.3(B) needs main breaker and backfed clip shop p/s needs 2 grd rods, 250.32, 250.119(A) shall not ID #6 or smaller equip grd
|
ELE07-03789
| Electrical Rough-In | 12/3/2007 | 12/3/2007 | 12/3/2007 2:43:00 PM | P | PART |
|
|
dale Note: please call 1/2 hr prior to inpsection so he show where to see Phone #: ###-#### u/g ok only
|
ELE07-03983
| Temporary Service | 12/3/2007 | 12/3/2007 | 12/3/2007 2:05:42 PM | P | PASS |
|
|
Contact is Brian Cornell. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery t/s u/g new ok
|
ELE07-03982
| Electrical Rough-In | 12/3/2007 | 12/3/2007 | 12/3/2007 1:31:17 PM | P | PASS |
|
|
jay - ###-#### r/i ok needs 15 amp for jtub circuits, and use only manufactures listed breakers called
|
ELE07-03971
| Electrical Rough-In | 12/3/2007 | 12/3/2007 | 12/3/2007 12:45:29 PM | P | PART |
|
|
Stu, this uis for Su. 100; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt walls, and hard ceiling rest rm
|
ELE07-03971
| Permanent Service | 12/3/2007 | 12/3/2007 | 12/3/2007 12:44:31 PM | P | PASS |
|
|
Stu, this uis for Su. 100; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt p/s u/g new for meter
|
ELE07-00358
| Final | 12/3/2007 | 12/3/2007 | 12/3/2007 11:48:40 AM | A | PASS |
|
|
|
ELE07-02903
| Final | 12/3/2007 | 12/3/2007 | 12/3/2007 10:44:07 AM | A | PASS |
|
|
Thank You!! Phone #: ###-#### Internet Inspection Request from: Tracy ok no card
|
ELE07-03907
| Temporary Service | 12/3/2007 | 12/3/2007 | 12/3/2007 9:45:44 AM | A | FAIL |
|
|
Contact is Brian Cornell. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery called needs seperate permit for t/s
|
ELE07-03888
| Electrical Rough-In | 11/30/2007 | 12/3/2007 | 12/3/2007 9:25:51 AM | A | FAIL |
|
|
Please call at least 20 mins prior to inspection-Ron holden Phone #: ###-#### 300.4 nail plates and 11/4", 110.3(B) p/s at shop needs main breaker, 314.23 &B C C no cutin boxes for new construction, needs conn for GEC, B C C complete all makeup, 314.3 needs bond bushing metal raceway in plastic jbox at house, 352.12(C) needs schedule 80 for exposed sections of PVC, grd to concrete encased electrode
|
ELE07-03905
| Electrical Rough-In | 11/30/2007 | 12/3/2007 | 12/3/2007 8:26:09 AM | A | PART |
|
|
craig Note: wall Phone #: ###-#### walls ok
|