ELE13-03125
| Conference | 12/3/2013 | 12/3/2013 | 12/3/2013 3:20:00 PM | P | DONE |
|
|
Contact- Tom Hartung Phone #: ###-#### >> Inspection requested via web by Deb Gooden Discussed with contractor floor penetrations, service outlet for rooftop equipment
|
ELE13-03351
| Electrical Rough-In | 12/3/2013 | 12/3/2013 | 12/3/2013 2:33:45 PM | P | PASS |
|
|
Any questions, please call me at ###-####. Thank You!!!! Phone #: ###-#### >> Inspection requested via web by Clay Morgan rough-in ok cover trench between house and detached garage
|
ELE13-03089
| Final | 12/2/2013 | 12/3/2013 | 12/3/2013 2:10:06 PM | P | PASS |
|
|
Call me before you go so I can make sure home owner is there thank you Phone #: ###-#### >> Inspection requested via web by Neal Rumsey UL listed Class A GFCI in thermostat, final ok
|
ELE13-03282
| Final | 12/3/2013 | 12/3/2013 | 12/3/2013 1:41:40 PM | P | PASS |
|
|
carl Phone #: ###-#### final ok
|
ELE13-02802
| Final | 12/3/2013 | 12/3/2013 | 12/3/2013 1:30:53 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov final ok
|
ELE13-01498
| Final | 12/2/2013 | 12/3/2013 | 12/3/2013 12:56:02 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by HZ ZAHIC NEC 2210.4 Multiwire branch circuits shall provide simultanously disconnecting means NEC 210.5 Identified white conductors as current carrying conductor A/C circuit. Could not test all receptacles, furniture already moved in
|
ELE13-03349
| Final | 12/2/2013 | 12/3/2013 | 12/3/2013 12:00:36 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by robert feller final ok
|
ELE13-03349
| Electrical Rough-In | 12/3/2013 | 12/3/2013 | 12/3/2013 12:00:07 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by robert feller RU listed spa rough-in ok
|
ELE13-03343
| Electrical Rough-In | 12/2/2013 | 12/3/2013 | 12/3/2013 10:22:46 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by BARRY KENDALL rough-in ok cover walls
|
ELE13-03006
| Electrical Rough-In | 12/3/2013 | 12/3/2013 | 12/3/2013 9:53:55 AM | A | PASS |
|
|
Floor heat Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in ok cover UL listed floor heat 3 locations
|
ELE13-03341
| Electrical Rough-In | 12/2/2013 | 12/3/2013 | 12/3/2013 9:18:48 AM | A | PASS |
|
|
This is not a rough and service inspection. This is inspection of the soffits only please. Call Jim if you have any questions. Thanks. Phone #: ###-#### >> Inspection requested via web by Paula Gratiot rough-in ok cover exterior soffits
|
ELE13-03325
| Permanent Service | 12/2/2013 | 12/3/2013 | 12/3/2013 8:47:26 AM | A | PASS |
|
|
Tim Phone #: ###-#### corrections done, p/s o/h rec ok
|
ELE13-03181
| Electrical Rough-In | 12/2/2013 | 12/3/2013 | 12/3/2013 8:45:32 AM | A | PASS |
|
|
Tim Phone #: ###-#### corrections done, p/s o/h rec ok
|
ELE13-03275
| Final | 12/2/2013 | 12/3/2013 | 12/3/2013 8:45:30 AM | A | PASS |
|
|
Please call for job details. Phone #: ###-#### >> Inspection requested via web by Rex Boyles final ok
|