ELE15-03936
| Permanent Service | 12/30/2015 | 12/30/2015 | 12/30/2015 2:26:12 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender 110.9- Equipment intended to interupt current at fault levels shall have an interupting rating sufficient for fault current available at line terminals. 13,283 available fault current on 10,000 rated main breaker.
|
ELE15-03489
| Electrical Rough-In | 12/29/2015 | 12/30/2015 | 12/30/2015 2:03:07 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by ERIC CENTERS Wall rough in ok cover
|
ELE15-04120
| Electrical Rough-In | 12/30/2015 | 12/30/2015 | 12/30/2015 1:20:32 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder Kitchen layout staying same with addition of receptacles to serve counter top to todays code. Rough in ok cover
|
ELE15-03117
| Electrical Rough-In | 12/30/2015 | 12/30/2015 | 12/30/2015 12:42:14 PM | P | CANC |
|
|
service inspection, Greg Milburn is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce Needed permanent service inspection
|
ELE15-03117
| Permanent Service | 12/30/2015 | 12/30/2015 | 12/30/2015 12:41:47 PM | P | PASS |
|
|
service inspection, Greg Milburn is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce p/s u/g n ok
|
ELE15-04130
| Electrical Rough-In | 12/30/2015 | 12/30/2015 | 12/30/2015 10:45:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Kitchen and M. bath rough in ok cover
|
ELE15-03386
| Final | 12/29/2015 | 12/30/2015 | 12/30/2015 10:04:06 AM | A | PASS |
|
|
Call for access code Thanks, Greg Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
|
ELE15-03764
| Final | 12/28/2015 | 12/30/2015 | 12/30/2015 9:42:35 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by cris flores 210.8- All 120 volt receptacle outlets located within 6' of sinks shall have GFCI protection. Bath GFCI dead and outlet in laundry area not working.
|
ELE15-03764
| Electrical Rough-In | 12/30/2015 | 12/30/2015 | 12/30/2015 9:27:58 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cris flores Grid rough in ok cover
|
ELE15-03599
| Final | 12/29/2015 | 12/30/2015 | 12/30/2015 9:09:48 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Final ok
|
ELE15-04080
| Rough-In Permanent Service | 12/29/2015 | 12/30/2015 | 12/30/2015 8:47:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cal crosby Rough in ok cover p/s u/g n ok
|