Inspections for the day of: Monday, December 30, 2019.
Number of inspections: 26
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05725 Final12/30/201912/30/201912/30/2019 3:46:30 PMPPASS
Lynwana Avery; El-Ada #A-12957 Phone #: ###-#### Inspection requested via web by Loren Bailey- furnace a/c coil co locking caps ok
MEC19-05355 Final12/26/201912/30/201912/30/2019 3:22:04 PMPNH
Please call Shawn in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- called number listed twice straight to voice mail- went by no one home- reschedule
MEC19-02407 DOC - Permit Finaled12/30/201912/30/201912/30/2019 3:17:51 PMPPASS
final ok- plumbing permit issued
MEC19-05729 Final12/30/201912/30/201912/30/2019 3:04:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace co ok
MEC19-05693 Final12/27/201912/30/201912/30/2019 2:41:04 PMPPASS
please call our lead installer Brad when 30-45 mins before so he can have the flue under pressure when you arrive Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co locking caps ok- 5lb flue pass
MEC19-05449 Final12/26/201912/30/201912/30/2019 2:16:52 PMPPASS
Please call Erika ###-#### in route to inspection Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co locking caps ok
MEC19-04774 Final12/29/201912/30/201912/30/2019 1:28:04 PMPNR
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need air balance, need duct blast, condenser needs set etc
MEC19-05755 Rough-in12/30/201912/30/201912/30/2019 12:53:54 PMPFAIL
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum
1- need city approved man j onsite none found
2- need to remove stucco around gas line penetration at meter and install 10 mil inert tape on pipe and retest gas line
MEC19-05746 Final12/30/201912/30/201912/30/2019 12:36:03 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
MEC19-05794 DOC - Permit Finaled12/30/201912/30/201912/30/2019 12:11:24 PMPPASS
final ok
MEC19-05794 Pressure Test12/27/201912/30/201912/30/2019 12:10:32 PMPPASS
INSTALLER JOHN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass co installed
MEC19-05450 Rough-in12/27/201912/30/201912/30/2019 11:34:02 AMAPART
Duct Seal Inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- center stairwell to west seal on all duct ok ok ti insulate excluding 3 rooms and existing RTU to move- call in when ready
MEC19-05812 Rough-in12/30/201912/30/201912/30/2019 10:53:12 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
MEC19-05812 Pressure Test12/30/201912/30/201912/30/2019 10:52:49 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location
MEC19-05811 Rough-in12/30/201912/30/201912/30/2019 10:52:23 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
MEC19-05811 Pressure Test12/30/201912/30/201912/30/2019 10:52:09 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location- 5lb flue pass
MEC19-04687 Final12/28/201912/30/201912/30/2019 10:21:18 AMAPASS
final inspection of 75k gas heater installed in shop behind the residence.. The only discrepancy found in final inspection is I had to add a third metal barrier in the wall for against the installation for the double wall exhaust stainless pipe to exit-all complete. Any time after 10AM AM or PM please text or call is fine, thanks Phone #: ###-#### Inspection requested via web by ron powell- final ok
MEC19-05787 Final12/27/201912/30/201912/30/2019 10:06:03 AMAPASS
Please call Mike Thompson the tech at ###-#### 1 hour prior to arrival so he can get the flue under pressure. Furnace was installed Friday 12/27/19 but the flue wasn''t ready for inspector. Phone #: ###-#### Inspection requested via web by Alyssa Cromwell- furnace co ok
MEC19-05787 Pressure Test12/27/201912/30/201912/30/2019 9:56:42 AMAPASS
Please call Mike Thompson the tech at ###-#### 1 hour prior to arrival so he can get the flue under pressure. Furnace was installed Friday 12/27/19 but the flue wasn''t ready for inspector. Phone #: ###-#### Inspection requested via web by Alyssa Cromwell- 5lb flue test pass
MEC19-05709 Rough-in12/27/201912/30/201912/30/2019 9:20:42 AMAPASS
Joe Phone #: ###-####- R/I ok
MEC19-05709 Pressure Test12/30/201912/30/201912/30/2019 9:20:27 AMAPASS
Joe Phone #: ###-####-m 20lb gas pass tagged meter location
MEC19-05725 Final12/26/201912/30/201912/30/2019 8:58:01 AMAFAIL
Lynwana Avery; El-Ada #A-12957 Phone #: ###-#### Inspection requested via web by Loren Bailey- furnace a/c coil co locking caps ok- condensate for furnace needs condensate pump installed and ran to washer box and pump needs wired for emergency shutoff- recall in when ready
MEC19-05253 Rough-in12/27/201912/30/201912/30/2019 8:40:50 AMAFAIL
call ###-#### when on the way Phone #: ###-#### Inspection requested via web by Lindsey Stegemann- framing horizontal header is touching pipe needs 1" min clearance- need to firecaulk exterior penetration at thimble inside- gas piping needs stub thru appliance or sleeve csst
MEC19-00866 Mec-Aging Inspection12/30/201912/30/201912/30/2019 7:56:17 AM DONE
MEC19-00866 DOC - Permit Expired12/30/201912/30/201912/30/2019 7:56:06 AMAPASS
no calls- no activity- permit expired
MEC19-04775 Final12/29/201912/30/201912/29/2019 11:01:55 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak