Inspections for the day of: Tuesday, December 31, 2013.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01656 ELE-Aging Inspection12/31/201312/31/20131/6/2014 6:25:27 AM CANC
ELE13-02852 Final12/31/201312/31/20131/2/2014 8:56:22 AMPPART
Call Steve McCloy; Executive area final inspection (2nd floor; North building; West corner) Phone #: ###-#### >> Inspection requested via web by Steve McCloy nw executive area only ok final, will sign card later, partial occuppancy for some offices other area will be allowed subject to inspection later
ELE13-03563 Final12/31/201312/31/20131/2/2014 8:06:50 AMPPASS
wired hood and rtu, some repairs- added outlets - call rocky @ ###-#### manager but said he b there allday this could wait till thurs. but let owner know ty dennis Phone #: ###-#### >> Inspection requested via web by dennis mcneely ok final, signed card
ELE13-03544 Electrical Rough-In12/31/201312/31/201312/31/2013 3:06:15 PMPPASS
Contact: Marty Vanness. underground inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden u/g ok
ELE13-03481 Electrical Rough-In12/31/201312/31/201312/31/2013 2:45:11 PMPPASS
Please re-inspect for outlet coverage. Phone #: ###-#### >> Inspection requested via web by Kendra Lanham corrections made, ri ok
ELE13-02486 Final12/31/201312/31/201312/31/2013 2:12:37 PMPFAIL
Thank you Phone #: ###-#### >> Inspection requested via web by Chris Chesnut called, too many items too list, some items: dead outlets in garage,washer not on gfci,fan box open at front door, bath gfci's won't set, kitchen plugs dead, outlet spacing in kitchen not per code, dining room outlet dead, hall receptacle dead, no light switches for up lights in big room, loose bath receptacle down bath, service riser shall be strapped, breakers labelled, ground bar for intersystem bond shall be installed, if balcony over 20 sq feet, shall add outlet
ELE13-03575 Rough-In Permanent Service12/31/201312/31/201312/31/2013 12:50:58 PMPPASS
after 2:00 lock box code is 7534 Phone #: ###-#### >> Inspection requested via web by shane miller ri ok, p/s o/h rec ok
ELE13-00748 Conference12/31/201312/31/201312/31/2013 12:20:09 PMPDONE
Josh Phone #: ###-#### talked about progress on house
ELE13-03511 Electrical Rough-In12/30/201312/31/201312/31/2013 10:41:06 AMAPASS
luke Phone #: ###-#### called, will see rest at final, ri ok, whole shopping center being done, except north store
ELE13-03458 Electrical Rough-In12/30/201312/31/201312/31/2013 10:09:45 AMAPASS
ceiling cover inspection call corey with questions thanks Phone #: ###-#### >> Inspection requested via web by Don Lustig corrections made, ok cover nw ceiling only
ELE13-03269 Final12/30/201312/31/201312/31/2013 9:38:25 AMAPASS
Please call prior to arrival for access. Phone #: ###-#### >> Inspection requested via web by Patrick Paz ok final
ELE13-03481 Electrical Rough-In12/30/201312/31/201312/31/2013 9:26:58 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Kendra Lanham called shall strap nm cable within 12" of panel, shall provide receptacles per 210.52, owner will pull back insulation as required if outlets not done before
ELE13-02937 Final12/30/201312/31/201312/31/2013 8:52:45 AMAPASS
Garage entrance code 1979E. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
ELE13-02759 Final12/30/201312/31/201312/31/2013 8:47:45 AMAPASS
Garage code 1979E. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
ELE13-03575 Permanent Service12/31/201312/31/201312/31/2013 6:41:21 AMPCANC
after 2:00 Phone #: ###-#### >> Inspection requested via web by shane miller Inspection cancelled from web by: shane miller