ELE14-03043
| Electrical Rough-In | 12/31/2014 | 12/31/2014 | 12/31/2014 12:17:32 PM | P | PASS |
|
|
Contact is Alan Krishnek Phone #: ###-#### Inspection requested via web by Scott Campbell Walls ok to cover womens bathroom floor 1 and 2, outlets to fountain in halls floor 1 and 2
|
ELE12-01075
| Final | 12/31/2014 | 12/31/2014 | 12/31/2014 11:46:28 AM | P | PASS |
|
|
Contact Rob Mairs for access ###-#### Phone #: ###-#### Inspection requested via web by steve ragan Elevator room Final OK
|
ELE14-03006
| Final | 12/30/2014 | 12/31/2014 | 12/31/2014 10:55:42 AM | A | PASS |
|
|
Inspection requested via web by Terry Scott corrections made, final OK
|
ELE14-02915
| Final | 12/30/2014 | 12/31/2014 | 12/31/2014 10:49:55 AM | P | PASS |
|
|
correction complete, smokes moved to afci. Phone #: ###-#### Inspection requested via web by shane vigil corrections made, final OK
|
ELE12-00053
| ELE-Aging Inspection | 12/31/2014 | 12/31/2014 | 12/31/2014 10:26:51 AM | | DONE |
|
|
Called Gary, he will try and get insp. scheduled next week.
|
ELE14-03261
| Final | 12/30/2014 | 12/31/2014 | 12/31/2014 10:22:23 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Barbara Szurgot final ok
|
ELE14-03515
| Electrical Rough-In | 12/31/2014 | 12/31/2014 | 12/31/2014 10:02:59 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender 334.30 nm cable shall be secured at intervals no greater than 4 1/2 feet 300.4.1 cable through bored holes shall have protection when hole is less than 1 1/4 inche from edge of framing member 300.4.D cable run parallele to framing member shall be supported so edge of cable is no less than 1 1/4 inch from edge of framing member 210.52 rececptacles shall be installed so that no wall space is greater than 6 foot from a receptacle 210.11 bathroom outlets shall be supplied by 20 amp circuit and supply no other loads. WUI Zone: soffit cans require 2 hour minimum fire barrier called contractor
|
ELE11-00558
| Final | 12/31/2014 | 12/31/2014 | 12/31/2014 8:50:32 AM | A | PASS |
|
|
Access to back yard open, homeowner is out of town Phone #: ###-#### Inspection requested via web by Lynn Cable final ok
|
ELE14-03006
| Final | 12/30/2014 | 12/31/2014 | 12/31/2014 6:04:22 AM | A | CANC |
|
|
Inspection requested via web by Terry Scott Contractor doubled the final inspection request, removing one.
|