Inspections for the day of: Tuesday, December 31, 2019.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04788 Electrical Rough-In12/30/201912/31/201912/31/2019 1:10:00 PMPPASS
Please call me for access 30 min prior, I have the key! thx Steve Phone #: ###-#### Inspection requested via web by Steven Meredith ANSUL system rough in only. All surface mount conduit. 20/20 quad breaker needs replaced with 15/15 quad as per nameplate on ANSUL panel. Need to check RTU on final after VFD's have been enrgized.
ELE19-00833 Conference12/30/201912/31/201912/31/2019 12:34:25 PMPPASS
Please call me on this also to coordinate for access and hopeful project close out! Phone #: ###-#### Inspection requested via web by Steven Meredith Contractor looking to close permit. Demo only. Will wait till new contractor has pulled a permit for reinstall as there are still lockouts on Electrical room.
ELE19-04938 Electrical Rough-In12/30/201912/31/201912/31/2019 12:26:23 PMPPASS
Underground for floor plugs and island Phone #: ###-#### Inspection requested via web by Zane Robertson underground ok to cover
ELE19-04901 Permanent Service12/31/201912/31/201912/31/2019 11:44:42 AMPPASS
please reinspect. Fault current calculation is posted inside the front cover of the metering center. Phone #: ###-#### Inspection requested via web by David Mackey Correction made p/s u/g n ok
ELE19-04943 Final12/31/201912/31/201912/31/2019 11:44:03 AMPNR
please call brodie @ with any questions ###-####. Replacing pedestal Phone #: ###-#### Inspection requested via web by William Salts Call for final after energized
ELE19-04943 Permanent Service12/31/201912/31/201912/31/2019 11:26:47 AMAPASS
please call brodie @ with any questions ###-####. Replacing pedestal Phone #: ###-#### Inspection requested via web by William Salts RV pedistall p/s u/g n ok
ELE19-04944 Electrical Rough-In12/31/201912/31/201912/31/2019 11:17:42 AMPPASS
floor heat inspection Phone #: ###-#### Inspection requested via web by Barbara Szurgot Master floor heat ok to cover
ELE19-04931 Final12/30/201912/31/201912/31/2019 10:23:37 AMAPASS
Please contact Jason Noble at ###-#### Phone #: ###-#### Inspection requested via web by Deb Gooden final ok
ELE19-04931 Electrical Rough-In12/31/201912/31/201912/31/2019 10:23:21 AMPPASS
Please contact Jason Noble at ###-#### Phone #: ###-#### Inspection requested via web by Deb Gooden All wire fished in. 120v circuit to hot tub ok
ELE19-04906 Electrical Rough-In12/30/201912/31/201912/31/2019 9:52:35 AMAFAIL
brian Phone #: ###-#### 240.4D 14awg wire is only good for 15Amps. Adding to 20 Amp circuits. All wire shall be 12awg
ELE19-04516 Electrical Rough-In12/30/201912/31/201912/31/2019 9:48:34 AMAPASS
North west
Underground to building Phone #: ###-#### Inspection requested via web by Stephanie Huston Underground from main gear to parking garage (running E to W) ok to cover