ELE02-03728
| Temporary Service | 12/3/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | A | FAIL |
|
|
###-####
408.21 Grounded Conductor Terminations.
Each grounded conductor shall terminate within the panelboard in an individual terminal that is not also used for another conductor.
406.8 Receptacles in Damp or Wet Locations.
(B) Wet Locations.
(1) 15- and 20-Ampere Outdoor Receptacles. 15- and 20-ampere, 125- and 250-volt receptacles installed outdoors in a wet location shall have an enclosure that is weatherproof whether or not the attachment plug cap is inserted.
527.6 Ground-Fault Protection for Personnel.
(B) Use of Other Outlets. Receptacles other than 125-volt, single-phase, 15-, 20-, and 30-ampere receptacles shall have protection in accordance with (1) or, the assured equipment grounding conductor program in accordance with (2).
(1) GFCI Protection. Ground-fault circuit interrupter protection for personnel.
12/4/2002 10:55:02 AM
|
ELE02-03371
| Electrical Rough-In | 12/3/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 12/03/2002 at 15:57:06. Contact: ###-####.
|
ELE02-01749
| Final | 12/3/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | A | NR |
|
|
###-####
still working on laundry room and found reversed polarity and line to load reversed.
I checked outside and garage outlets ok 12/4/2002 10:57:02 AM
|
ELE02-03261
| Electrical Rough-In | 12/3/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 12/03/2002 at 12:00:37. Contact: ###-####.
Loose set screws, unsecured boxes, over 360 deg. bend. 12/4/2002 8:52:40 AM
|
ELE02-02349
| Final | 12/3/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | P | CANC |
|
|
SCOTT; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
ELE02-03261
| Electrical Rough-In | 12/4/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | P | PART |
|
|
allan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
Partial wall R/I Ok 12/4/2002 4:22:17 PM
|
ELE02-03747
| Rough-In Permanent Service | 12/4/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | P | PASS |
|
|
kenny -- ###-####
P/S O/H R Ok
to transfer power 12/4/2002 3:12:47 PM
|
ELE02-02597
| Final | 12/4/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | P | PASS |
|
|
re-insp- doug- ###-####
|
ELE02-02349
| Permanent Service | 12/4/2002 | 12/4/2002 | 12/4/2002 12:00:00 AM | P | PASS |
|
|
P/S O/H N OK
not finaled
|