ESC09-00350
| General Inspection | 12/4/2009 | 12/4/2009 | 12/4/2009 4:10:37 PM | P | PASS |
|
|
looked ok
|
ELE09-01285
| Electrical Rough-In | 12/3/2009 | 12/4/2009 | 12/4/2009 4:10:05 PM | P | PASS |
|
|
ceiling cover, Toby Groves, ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis outside soffits only ok to cover, no esc this project
|
ELE09-02312
| Permanent Service | 12/3/2009 | 12/4/2009 | 12/4/2009 3:54:52 PM | P | FAIL |
|
|
Guy Phone #: ###-#### met contractor early, looked at part of installation, talked with 412, told contractor only 1 service allowed for building per NEC 230, no esc this project
|
ESC08-00776
| General Inspection | 12/4/2009 | 12/4/2009 | 12/4/2009 3:22:06 PM | P | PASS |
|
|
looked ok
|
ELE09-02338
| Final | 12/4/2009 | 12/4/2009 | 12/4/2009 2:38:15 PM | P | PASS |
|
|
Rick at ###-#### or Kelly at ###-#### Starbucks Inside Albertsons Store . Electrical Phone #: ###-#### Internet Inspection Request from: Kelly Felin ok to final, signed structural card, no esc this project
|
ELE09-02319
| Electrical Rough-In | 12/3/2009 | 12/4/2009 | 12/4/2009 2:09:41 PM | P | PASS |
|
|
WE ARE EXPECTING TO BE DONE AT ABOUT 1:30, WE WOULD LIKE TO BE THERE WHEN YOU INSPECT IF IT WORKS OUT. WE WILL BE CLEANING UP FOR A WHILE SO HOPEFULLY WE WILL SEE YOU THERE. THANKS. Phone #: ###-#### Internet Inspection Request from: Jamie Winters ric ok, told electrician to change room count to 11 rooms on permit
|
ELE09-02319
| Permanent Service | 12/4/2009 | 12/4/2009 | 12/4/2009 2:09:24 PM | P | PASS |
|
|
WE ARE EXPECTING TO BE DONE AT ABOUT 1:30, WE WOULD LIKE TO BE THERE WHEN YOU INSPECT IF IT WORKS OUT. WE WILL BE CLEANING UP FOR A WHILE SO HOPEFULLY WE WILL SEE YOU THERE. THANKS. Phone #: ###-#### Internet Inspection Request from: Jamie Winters p/s u/g n ok
|
ELE09-01932
| Electrical Rough-In | 12/3/2009 | 12/4/2009 | 12/4/2009 1:08:39 PM | P | FAIL |
|
|
Late in the afternoon if possible. Nick is the contact his no. is ###-####. Phone #: ###-#### Internet Inspection Request from: Shawna Gates called, left correction notice,NEC 110.12(A) shall close unused openings, 300.11(a)(1) cables and raceways shall not be supported bt ceiling grid wires, 314.25 shall provide cobers for switches and receptacles, 406.4 receptacles shall be securely supported, 330.30(A) mc cable shall be secured within 12" of box, BCC No violations shall be retained
|
ELE09-02282
| Final | 12/4/2009 | 12/4/2009 | 12/4/2009 12:01:56 PM | P | PASS |
|
|
Steve Phone #: ###-#### ok to final, signed structural card, no esc this project
|
ELE07-03990
| Final | 12/4/2009 | 12/4/2009 | 12/4/2009 9:53:28 AM | A | PASS |
|
|
ok to final, no esc this project
|
ELE09-02347
| Electrical Rough-In | 12/3/2009 | 12/4/2009 | 12/4/2009 9:51:53 AM | A | CANC |
|
|
Please call 1/2 hour before inspection so we can meet you there. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty
|
ELE06-00293
| ELE-Aging Inspection | 12/4/2009 | 12/4/2009 | 12/4/2009 9:30:50 AM | | DONE |
|
|
no activity
|
ELE07-03996
| ELE-Aging Inspection | 12/4/2009 | 12/4/2009 | 12/4/2009 9:30:27 AM | | DONE |
|
|
no activity
|
ELE09-01418
| Electrical Rough-In | 12/3/2009 | 12/4/2009 | 12/4/2009 9:24:28 AM | A | PASS |
|
|
Inspection for the groud work call Dustin at listed number with Questions Thank you Phone #: ###-#### Internet Inspection Request from: David Oliver ok to cover u/g from transformer to cell building- part will be core drilled across parking lot, no esc this project
|
ELE09-02346
| Permanent Service | 12/3/2009 | 12/4/2009 | 12/4/2009 9:02:48 AM | A | PASS |
|
|
service located in south west back corner of lot. Phone #: ###-#### Internet Inspection Request from: Cindie Swaim p/s o/h n ok, no esc this project
|
ELE09-02310
| Electrical Rough-In | 12/3/2009 | 12/4/2009 | 12/4/2009 8:16:11 AM | A | PASS |
|
|
Underground Phone #: ###-#### Internet Inspection Request from: Mark Sessions ok to cover u/g to panels (4) anop, no esc this project
|