Inspections for the day of: Thursday, December 4, 2014.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorCevyn Recla
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02415 ELE-Aging Inspection12/4/201412/4/201412/5/2014 6:41:33 AM DONE
Spoke to contractor about permit having failed inspection, power is on at address. Turned over to Chief electrical inspector.
ELE14-03320 Final12/2/201412/4/201412/4/2014 7:05:51 PMPCANC
100amp service change Call Lonnie @###-#### Phone #: ###-#### Inspection requested via web by Andy Rose
cancelled
ELE14-02714 Final12/4/201412/4/201412/4/2014 2:32:34 PMPCANC
Please call 1 hour before arriving ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman
wrong ispection type
ELE14-02714 Electrical Rough-In12/4/201412/4/201412/4/2014 2:32:17 PMPPASS
Please call 1 hour before arriving ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman
cable floor heat, master bath area, ok to cover
ELE14-03339 Electrical Rough-In12/4/201412/4/201412/4/2014 2:13:25 PMPPASS
Please call Doug at ###-#### before going there. Thanks Phone #: ###-#### Inspection requested via web by Barbara Szurgot
RI OK to cover, kitchen area and entertainment area in living
ELE14-03320 Permanent Service12/4/201412/4/201412/4/2014 1:57:47 PMPPASS
100amp service change Call Lonnie @###-#### Phone #: ###-#### Inspection requested via web by Andy Rose
PS, OH, N, OK
ELE14-03218 Final12/4/201412/4/201412/4/2014 1:35:10 PMPPASS
Robert Phone #: ###-####
Final OK
ELE14-03343 Final12/4/201412/4/201412/4/2014 1:03:56 PMPCANC
Phone #: ###-#### Inspection requested via web by Jason Wicks needed RIPS inspection
ELE14-03343 Rough-In Permanent Service12/4/201412/4/201412/4/2014 1:03:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Jason Wicks
See permit ELE14-03314 for corrections
Corrections have been addresed, Basement was wired without permit, contractor has opened at many points for inspection. Visual inspection allowed wtih Daryl DeGrange. OK to cover
PS, OK, RC, OK
ELE14-03339 Conference12/4/201412/4/201412/4/2014 10:38:29 AMPCANC
Please call Doug at ###-#### before going there. Thanks Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot Inspection cancelled from web by: Barbara Szurgot
ELE12-00194 ELE-Aging Inspection12/4/201412/4/201412/4/2014 9:54:12 AM DONE
Left message
ELE14-03331 Permanent Service12/3/201412/4/201412/4/2014 9:22:56 AMAFAIL
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering. Phone #: ###-#### Inspection requested via web by Stephen Kren
Cannot see any grounding at main service, need 2 ground rods, or they need to be uncovered for inspection. Interior panels are no longer being used and have been converted to junction points, the lids need to be secured shut.
ELE14-03326 Conference12/3/201412/4/201412/4/2014 8:54:14 AMADONE
Phone #: ###-#### Inspection requested via web by Jamie Winters
conference to discuss wiring of existing detached garage, install disconnect at nearest point of entrance and bring grounding up to code.
ELE14-01652 Electrical Rough-In12/3/201412/4/201412/4/2014 8:41:59 AMAPASS
Josh Phone #: ###-####
RI, OK to cover